  1. Number of the object from which the event is received.
  2. Type of the object from which the event is received.
  3. Name of the object from which the event is received.
  4. Event name.
  5. Set event parameters (from 0 to N).

Each event is sending in separate TransactionBlock with unique FunctionNumber parameter. FunctionNumber is specified automatically and it's unique for each event among all NEXT objects in the system.

Low bound of a FunctionNumber values range is specified by FunctionNumberMinValue registry key in the HKEY_LOCAL_MACHINE\SOFTWARE\ITV\Intellect registry section.

Sent XML packages look like:

<TransactionBlock>
    <TransactionDate>02.08.10</TransactionDate>
    <TransactionTime>19:53:51</TransactionTime>
    <FunctionNumber>2000<<FunctionNumber>1001</FunctionNumber>
    <FunctionName>Intellect Event Event<ACCESS_IN</FunctionName>
    <ObjectId>1</ ObjectId >
   <ObjectType> Perco<ObjectType>Perco reader</ ObjectType >
   <ObjectName> Perco <ObjectName>Perco 1 reader</ ObjectName >
    <EventName>Access by ID <ID</ EventName >
    <param1>0</param1>
    <param0>0</param0>
</TransactionBlock>
<TransactionBlock>
    <TransactionDate>02.08.10</TransactionDate>
    <TransactionTime>19:54:51</TransactionTime>
    <FunctionNumber>1002</FunctionNumber>
    <FunctionName>Intellect Event ACCESS_DENIED</FunctionName>
    <ObjectId>1</ ObjectId >
    <ObjectType>Perco reader</ ObjectType >
    <ObjectName>Perco 1 reader</ ObjectName >
    <EventName>Access forbidden</ EventName >
    <param1>0</param1>
    <param0>0</param0>   <param1>10</param1>
</TransactionBlock>
Note
titleImportant!
The number and names of parameters can differ depending on the NEXT settings – see Selecting events to be sent to Axxon Next Server.