The Operator query panepanel object is the interface frame used to perform user specified functions with a user's set of elements. The elements are configured by the Intellect administrator in the ArpEdit utility (see the User’s Manual for ArpEdit ). The settings panel of the Operator query pane object is shown in figure.
...
Table describes the parameters of the settings corresponding to the elements of the settings panel of the Operator query panepanel object.
№
| Parameter | Method for setting the parameter value | Parameter description | Symbols used | Default value | Value range |
1 | Identifier* | Enter the value in the field | File name designed for certain PTZ unit control. The filename is usually the same as the name of the PTZ unit. | Latin, Cyrillic and service characters | - | A line containing a sequence of symbols (Latin and service characters, digits), not case-sensitive Number of symbols – from 1 to 16. |
2 | Name* | Enter the value in the field | Defines the name of the Operator query panepanel object in the digital distributed video surveillance system. To ensure user friendliness, the object name is usually given the same name as the name of the PTZ unit. | Latin, Cyrillic and service characters | Operator query panepanel | A line containing a sequence of symbols (Latin and service characters apart from > and < symbols, digits), not case-sensitive Number of symbols – from 1 to 60. |
3 | Disable | Is identified by the check mark | Defines the status of the Operator query panepanel object (enabled or disabled). | Boolean type | Not available | Yes – the Operator query panepanel object is disabled and is not in use. No – the Operator query panepanel object is enabled and is in use. |
4 | Computer | Is selected from the list | Defines the parent Computer object of the digital distributed video surveillance system, to which the given Operator query panepanel object refers. | Name of the Computer objects registered in the system | Name of the parent Computer object. | Depends on the number of Computer objects in the digital distributed video surveillance system |
5 | Allow moving | Is identified by the check mark. | Allows moving the Operator query panepanel over the screen using the mouse. | Boolean type | Not available | Yes – movement is allowed. No – movement is prohibited. |
Settings Group | ||||||
6 | X | Enter the value in the field. | Defines the coordinate in the X horizontal axis for the upper left corner of the Operator query panepanel on the screen. | % of the screen width. | Not defined | From 0 to M*100, where M is the number of surveillance monitors installed. |
7 | Y | Enter the value in the field. | Defines the coordinate in the Y vertical axis for the upper left corner of the Operator query panepanel on the screen. | % of the screen height. | Not defined | From 0 to M*100, where M is the number of surveillance monitors installed. |
8 | Monitor | Is selected from the list | Sets the computer monitor number, the to which coordinates are assigned | Sequence of numbers | 1 | 1 to 16 |
9 | Type | Is selected from the list | Defines the object type for displaying the Operator query panepanel. | Types of the objects registered in the system | Not defined | Depends on the number of types of objects created in the digital distributed video surveillance system. |
910 | Number | Is selected from the list | Defines the number of the object for displaying the Operator query panepanel. | Sequence of numbers | Not defined | Depends on the number of objects created in the digital distributed video surveillance system. |
1011 | Name | Automatically | Defines the name of the object for displaying the Operator query panepanel. | Names of the objects of the selected type registered in the system | Not defined | Depends on the number of objects types created in the digital distributed video surveillance system. |
1112 | Event | Is selected from the list | Defines the event, after which the Operator query panepanel is displayed | Types of events for the given types of devices. | Empty | Empty – the Operator query panepanel is not displayed. List of available events depends on the selected object. |
...