Go to documentation repository
Page History
...
- Low-level protocol. Events, reactions, configuration commands as the byte set are programmed to the software.
- SDK – Software Development Kit. Events, reactions, configuration commands, state requests as functionas are programmed to the software.
- Communication server (Program-driver) – program layer between ITV | AxxonSoft software and hardware in which events, reactions, configuration commands, state request are built in. COM-server and OPC-server are examples of these programs.
- SOFT-SOFT. Events, reactions, configuration commands, state requests are programmed on the level of two software packages. Database synchronization is a way of SOFT-SOFT integration on the level of joint using of one database by two software packages, e.g. for access to event log.
- Universal protocol integration: OPC, SNMP, BACnet. Exchange of events, reactions, configuration commands and state requests with hardware is performed by general protocol. List of hardware connected to the Intellect software package by universal protocols is specified in the Systems connected by universal protocols section.
Integrated hardware
...
Common name | Integrated hardware (name of devices) | Restrictions (monitoring, control, configuration) | Name in price-list | Information on manufacturer | Way of integration (low-level protocol, communication server, SDK, SOFT-SOFT) | Connection interface (RS-232, TCP\IP) |
Paradox | EVO48 ЕVO192 ACM12 | Monitoring, configuration, control | INTELLECT Access Control and Fire Alarm Service (Paradox), per COM port | Paradox Security Systems http://www.paradox.com/ | low-level protocol | RS-232, USB |
FoxSec | FS9000 FS7002PX (MK) FS7011PX (MK) | Monitoring, configuration, control | INTELLECT Access Control and Fire Alarm Service (Foxsec), per controller | FoxSec | low-level protocol | Ethernet |
ApolloSDK v.2 | AAN-100 AAN-32S AAN-32N AIM-2SL AIM-4SL AIO-168 ASA-72 | Monitoring, configuration, control | See detailed information in the Integration with Apollo SDK v.2 section | AAM Systems Office address: Kraznokazarmennaya str., 13-402 | SDK | RS-232, IP |
HID | EDGE ER40; VertX: v1000, v100, v200, v300, v2000, EVO Control reader HID Omnikey 5321 | Monitoring, configuration, control | INTELLECT Access Control Service (HID VertX/Edge), per reader | HID Glogal http://www.hidglobal.com | SDK | IP |
Honeywell Galaxy Dimension | Galaxy GD-48 Galaxy GD-96 Galaxy GD-264 Galaxy GD-520 DCM | Monitoring, configuration, control | INTELLECT Access Control and Fire Alarm Service (Honeywell Galaxy Dimension), per COM port | Honeywell Systems Group | low-level protocol | RS-232, Ethernet |
Systems connected by universal protocols
Operation of some systems is possible in the Intellect software package by universal integration modules (OPC Wrapper, BACnet Wrapper and SNMP Wrapper).
Systems which operation is guaranteed by OPC Wrapper universal integration are as follows:
Name | Functionality in the Intellect software package |
---|---|
Bosch (all devices works by the same OPC-server) | Monitoring, control (full list of supported states you can find here) |
FSA SIEMENS Cerberus-PRO |
|
ACS Gallagher 6000 |
|
MOXA cards (list of all cards which can be connected by the OPC-server is presented here) |
|
Systems which operation is guaranteed by BACnet Wrapper universal integration are as follows:
Name | Functionality in the Intellect software package |
---|---|
Sterownik FSG |
|
Systems which operation is guaranteed by SNMP Wrapper universal integration are as follows:
Name | Functionality in the Intellect software package |
---|---|
AVTECH - Room Alert 24E- Alarm Switch | Monitoring of the following events:
|
Axis A1001 | Monitoring of the following events:
|
Protection of universal integration modules
- OPC Wrapper: 1 IP-address. Several OPC servers can be in one IP-address.
- BACnet Wrapper: 1 device.
- SNMP Wrapper: 1 channel.