- Go to the settings panel of the AC ZK Controller C3-100 object.
- From the Gate: drop-down list select the type of controller connection: via Ethernet or RS-485 standard (1).
- In the Password: field enter the password for controller connection (2).
- In the IP: field enter the IP-address of the controller (3).
- From the Anti-passback: drop-down list select the rule of anti-passback operation (4):
- Disable – the anti-passback function is disabled
- Readers of Door 1 – the anti-passback function is enabled between the readers of Door 1.
- The Interlock function is always disabled for the single-door controller (45).
- From the Backup period: drop-down list select the time interval in minutes for saving the database backup (56).
Set the Watch dog checkbox to activate the control mode (67).
Info title Note. The version of firmware and serial number of controller will automatically display in the corresponding fields while connecting the controller (8).
- Click the Apply button (79).
Configuring of the C3-100 controller is completed.