  1. Go to the Hardware tab in the setting panel of INTELLECT™ (1).
  2. Create a PTZ device object under the Telemetry controller object or select the relevant object in the object tree in the Hardware tab of the System settings dialog box (2).

    Image Modified

  3. Specify the ID, the name of the PTZ device object and select the Telemetry controller object to which the PTZ device is connected (3).

  4. Select the ID of the camera equipped with a PTZ device (4).
  5. Select the name of the camera equipped with a PTZ device (5).

    Info
    titleNote

    Specify either the video camera ID or its name.

  6. If it is necessary to increase priority of the COM port specified in the settings of the Telemetry controller object, then set the Send commands to local port checkbox checked (6). This parameter is used when commands are sent not to COM port but to video capture card.

    Info
    titleNote.

    This setting is relevant when Stretch video capture cards are in use.

  7. In the Presets table set checkboxes checked next to the names of presets that are to be displayed on Telemetry control panel (see Telemetry control panel configuration section). Change the preset's name if necessary (76).

    Info
    titleNote

    In order to select all presets or cancel this operation, use the Select/Deselect checkbox (87).

  8. Set minimal and maximal speed of optical zoom in standard units for PTZ device in the Zooming speed group (98).

  9. Set minimal and maximal rotation speed in standard units for PTZ device while mouse control from the Monitor in the Mouse group (109).

  10. Set minimal and maximal rotation speed while joystick control in the Joystick group (1110)

  11. Set minimal and maximal rotation speed of PTZ device in direction of mouse click (Point&Click) in standard units for PTZ device in the Point&Click group (1211).

  12. Specify the MAC address of the PTZ device in the RS-232 address field. The PTZ MAC address corresponds to the address set on the PTZ device with the help of jumpers or configured while programming the PTZ device in the the bundled software (12).
  13. If the continuous PTZ mode (Continuous Mode) is to be disabled, set the Force disabling continuous PTZ mode checkbox checked (13).

    Info
    titleNote.

    If the checkbox is set unchecked, then the continuous PTZ mode is automatically enabled for the PTZ devices that support it.