№ | Parameter | Method for setting the parameter value | Parameter description | Symbols used | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Web-server object in the digital distributed video surveillance system. | Sequence of numbers | - | From 1 and above. Depends on the number of the Web-server objects in the digital distributed video surveillance system. |
2 | Name* | Type-in the value in the field | Sets the name of the Web-server object in the digital distributed video surveillance system. | Latin, Cyrillic and service characters | Web- server | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive Number of symbols – from 1 to 60. |
3 | Disable | Checkbox | Sets the state of the Web-server object (enabled or disabled) in the digital distributed video surveillance system. | Boolean type | No | Yes – the Web-server object is disabled and is not in use No – the Web-server object is enabled and is in use |
4 | Computer | Selected in the list | Sets the parent Computer object of the digital distributed video surveillance system, to which the given Web- server object refers. | Name of the Computer objects registered in the system | Name of the parent Computer object | Depends on the number of the Computer objects in the digital distributed video surveillance system |
The HTTP-server group | ||||||
5 | Port’s number | Type-in the value in the field | Sets the number of the port used by the HTTP server (for video surveillance with the Web-browser via the Internet). | Sequence of numbers | 80 | Any allowable port numbers which are not in use. The number of ports is defined by the system administrator. |
6 | Amount of connections | Type-in the value in the field | Sets the maximum allowable number of connections to the video server via the Web-server module. Each request to view the camera feed and each request to control all PTZ devices is considered as a user connection. | pcs | 100 | Any integer. In the case where 0 value is specified, video signals will not be displayed on the Web-server monitor. |
Without a group | ||||||
7 | Default user | Selected in the list | Sets the user with rights and authorities to conduct video surveillance from the Remote Workstation via the Web-server | The names of users registered in the system and added to the rights | Not set | Depends on the number of users registered in INTELLECT™ |
8 | ECHD translation | Set the checkbox | Enables http requests used for integration with ECHD. Attention! When enabling ECHD requests handling video surveillance using the Web browser becomes unavailable. | Boolean type | No | Yes – requests used for integration with ECHD are performed for the Camera objects under which the ECHD channel objects are created. No – requests used for integration with ECHD are not performed. |
9 | RTSP-server | Select value from the list | Sets rtsp server to process ECHD requests | Names of rtsp Server objects registered in the system | Not set | Depends on the number of rtsp Server objects in distributed digital surveillance system. |
The HTTPS server group | ||||||
10 | HTTPS protocol | Set checkbox | Enabling HTTPS protocol when transferring data via Web-server. | Boolean type | No | Yes – HTTPS protocol is in use. No – HTTPS protocol is not in use. |
11 | Key | Enter the value in the field | Key for data communication via HTTPS protocol. | Latin, Cyrillic letters and service characters | C:\Program Files (x86)\ Intellect\Modules\SSL\ssl_itv.key | Depends on the location of data encryption key when transferring data via HTTPS protocol. |
12 | Certificate | Enter the value in the field | Certificate for data communication via HTTPS protocol. | Latin, Cyrillic letters and service characters | C:\Program Files (x86)\Intellect\Modules\SSL\ssl_itv.cert | Depends on the location of certificate file when transferring data via HTTPS protocol. |
13 | Port number | Enter the value in the field | Sets the number of the port used for HTTPS server (used for video surveillance in the web browser and in the Internet). | Natural number series | 443 | Any allowable port numbers that are not in use. The number of ports is specified by the system administrator. |
The List of cameras tab | ||||||
14 | Range | Click the button | The box for adding cameras as a group is opened. | - | - | - |
16 | Clear | Click the button | The list of added cameras is cleared. | - | - | - |
15 | Add all | Click the button | All Camera objects created in the system are added to the list. | - | - | - |
17 | Number | Selected in the list | Sets the number of the camera video from which is transmitted to the remote workstation using the Web-server module. | IDs of the Camera objects registered in the system | Not specified | Depends on the number of cameras in the distributed video surveillance system. |
18 | Camera | Selected in the list | Sets the name of the video camera video from which is transmitted to the Remote Workstation via the Web-server module. | Names of the Camera objects registered in the system | Not set | Depends on the number of video surveillance cameras in the digital distributed video surveillance system |
19 | Video stream | Selected in the list | Sets the number of the video stream used for displaying in the Web-server interface | Numbers of video streams enabled on the camera and the By default value | By default | Depends on the number of enabled streams on the camera. |
20 | Live video | Selected in the list | Sets the source of live video to be displayed in the Web-server interface | Available means to get live video | Server | Server – live video is received from the Server to which the camera is connected. Videogate – live video is received from the Videogate. If a camera is not configured to transmit video through the Videogate, then this item is unavailable in the list. |
21 | Archive | Selected in the list | Sets the source of archive footage to be displayed in the Web-server interface | Available means to get archive video | Server | Server – archive footage is received from the Server to which the camera is connected. Videogate – archive footage is received from the Videogate. If a camera is not configured to transmit footage through the Videogate, then this item is unavailable in the list. Backup archive – archive footage is received from the Backup archive |
22 | Microphone | Select from a list | Specifies the name of microphone associated with the camera from which the sound will be passed through the Web-server | Names of registered Microphone objects in the system | Not specified | Depends on the number of microphones in the video surveillance system |
23 | Speaker | Select from a list | Specifies the name of speaker associated with the camera which will be in use to playback sound received from the client | Names of registered Speaker objects in the system | Not specified | Depends on the number of speakers in the video surveillance system |
24 | Compressionn | Selected in the list | Sets the compression ratio for video transmitted to Remote Workstations via the Web-server module. The higher the compression ratio the worse the video signal is. | Reference compression ratios | Not specified | Not specified, 1 – 5. Value “1” corresponds to minimum compression ratio, “5” – to maximum. If the compression ratio is not specified, video signal is transmitted with the same compression ratio as set for recording and transmitting video |
25 | Control | Selected in the list | Sets the camera control (arm/disarm, PTZ, recording to the archive) in accordance with user rights. | Boolean type | Enabled | Enabled – camera control in accordance with user rights is enabled. Disabled – camera control is disabled regardless of the user rights. |
...