Go to documentation repository
Page History
...
XML file | Parameter | Available values | Default | Product version | Parameter in effect |
---|---|---|---|---|---|
<Directory of the Intellect software installation>\Modules\Wt2\Web.config | CamMonitorShift | -5000 - 5000 | 0 | Sets shifting of video start while report viewing in milliseconds: >0 – video will start later than time specified in a report <0 – video will start earlier than time specified in a report | |
FaceReplaceCameraIpFrom | IP-address | - | up to 3.2 | Changes internal IP-address of a Server specified in the Architecture while viewing video for POS reports and for "Face" module report from outside | |
FaceReplaceCameraIpTo | IP-address | - | up to 3.2 | Changes external IP-address of a Server specified in the Architecture while viewing video for POS reports and for "Face" module report from outside | |
WorkThroughGateway | true, false | false | from 3.3 | Enables receiving video from Gateway while viewing video for POS reports and for "Face" module report. A Gateway is selected authomatically. | |
CommandTimeout | Time in secondsmilliseconds | 200 | Enables setting the timeout in secondsmilliseconds, during which waiting for data retrieval and report generation should occur. |
...