№ | Parameter | Method for setting the parameter | Parameter description | Symbols used | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Event viewer object in the digital distributed video surveillance system. | Sequence of numbers | - | From 1 and above. Depends on the number of Event Viewer objects in the digital distributed video surveillance system. |
2 | Name* | Type-in the value in the field | Sets the name of the Event viewer object in the digital distributed video surveillance system. | Latin, Cyrillic and service characters | Event Viewer | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive Number of symbols – from 1 to 60. |
3 | Disable | Checkbox | Sets the status of the Event viewer object (enabled or disabled) in the digital distributed video surveillance system. | Boolean type | No | Yes – the Event viewer is disabled and is not in use. No – the Event viewer is enabled and is in use. |
4 | Screen | Select in the list | Specifies the parent Display object of the digital distributed video surveillance system, to which the given Event viewer object refers. | Names of Display object s registered in the system | Name of the parent Display object . | Depends on the number of Display object s in the digital distributed video surveillance system. |
The Settings group | ||||||
5
| X | Type-in the value in the field
| Sets the coordinate in the X horizontal axis for the upper left corner of the window of the Event viewer interface object on the screen. | % of the screen width | Not set | From 0 to M*100, where M is the number of monitors installed. |
Y | Type-in the value in the field | Sets the coordinate in the Y vertical axis for the upper left corner of the window of the Event viewer interface object on the screen. | % of the screen height | Not set | From 0 to M*100, where M is the number of monitors installed. | |
6 | W | Type-in the value in the field | Sets the window width of the Event viewer interface object. | % of the screen width | Not set | From 0 to M*100, where M is the number of monitors installed. |
H | Type-in the value in the field | Sets the window height of the Event viewer interface object. | % of the screen width | Not set | From 0 to M*100, where M is the number of monitors installed. | |
7 | Monitor | Is selected in the list | The number of monitor in OS for which coordinates are specifying | Numbers of monitors | 1 | 1-16 |
8 | Allow moving | Checkbox | Allows the operator changing the position of the Event Viewer by clicking on it. | Boolean type | No | Yes – Operator can change the position of Event viewer. No – Operator cannot change the position of Event viewer. |
9 | Display video | Checkbox | Allows Operator viewing archive footage of the events, initiated by the Event Viewer as Record to disk using the Event viewer box. | Boolean type | No | Yes – Operator is allowed viewing the archive footage using the Event Viewer window. No – Operator is not allowed viewing the archive footage using the Event viewer window. |
10 | Display object on map | Checkbox | Allows Operator viewing objects, displayed in the Event viewer window, on the map.
| Boolean type | No | Yes - Operator is allowed viewing the objects, displayed in the Event Viewer window, on the map. No - Operator is not allowed viewing the objects, displayed in the Event Viewer window, on the map. |
11 | Display report | Checkbox | Allows Operator creating a printed form of the report and printing out the information about all events registered by the Event viewer within the pre-set period of time.
| Boolean type | No | Yes - Operator is allowed creating a printed form of the report and printing out the information about all events registered by the Event Viewer within the pre-set period of time. No - Operator is not allowed creating a printed form of the report and printing out the information about all events registered by the Event Viewer within the pre-set period of time. |
12 | Load protocol | Checkbox | Defines, whether or not the latest 1000 events registered by the Event viewer with the latest system start, should be downloaded with the launch of Intellect™ software. | Boolean type | No | Yes - the latest 1000 events registered by the Event viewer with the latest system start, should be downloaded with the launch of Intellect™ software. No - the latest 1000 events registered by the Event viewer with the latest system start, should not be downloaded with the launch of Intellect™ software. |
The Advanced settings group | ||||||
13 | View days | Type-in the value in the field | Sets the number of days to keep the event recording archive in the Intellect database. | Days | 1 | More than 1 |
14 | View events | Select in the list | Sets the events for displaying in the window of the Event Viewer. | - | All events | All events – all events are displayed in the Event Viewer window Last event – one last event is displayed in the Event Viewer window All last events – all last events are displayed for all selected objects |
15 | Background color | Select in the list or on the Select color panel. | Sets the background color in the Event Viewer box | RGB, CMY or HSL. | White | Corresponds to the standard range of the selected color system. |
16 | Text color | Select in the list or on the Select color panel. | Sets the text color in the Event Viewer box | RGB, CMY or HSL. | Black | Corresponds to the standard range of the selected color system. |
17 | Color of alarm messages | Select in the list or on the Select color panel. | Sets the color of the alarm messages in the Event viewer window. | RGB, CMY or HSL. | Red | Corresponds to the standard range of the selected color system. |
18 | Color of info messages | Select in the list or on the Select color panel. | Sets the color of the information messages in the Event viewer window. | RGB, CMY or HSL. | Blue | Corresponds to the standard range of the selected color system. |
19 | Duration of blinking, sec: | Type-in the value in the field | Sets the duration of alarm message blinking in the Event viewer window. | seconds | Not set | More than 0 |
20 | Font:<current font> | Click the button | Sets the font of information messages in the Event viewer window | Standard Font Windows dialog box | Depends on OS settings | - |
The Filters tab | ||||||
21 | Specify general background color | Click the button | Opens the window to select the message background color in the default filter | - | - | - |
22 | Specify general text color | Click the button | Opens the window to select the message text color in the default filter | - | - | - |
23 | Name | Specify the value in the field | Sets the filter name in the Event Viewer | Latin and Cyrillic alphabet, service digits | Filter 1, Filter 2, etc. | Depends on the number of created filters. |
24 | Type | Select in the list | Sets the types of objects to be displayed in the Event viewer. NOTE. If the field is empty, the Event viewer displays all events for all objects in the system. | Types of objects registered in the system. | Not set | Depends on the number of types of objects created in the digital distributed video surveillance system. |
25 | Number | Select in the list | Sets the identification number of the device. NOTE. If the field is empty, the Event viewer displays all events for all objects of the selected type. | Sequence of numbers | Not set | Depends on the number of created objects of the selected type in the digital distributed video surveillance system. |
26 | Name | Automatically | Specifes the name of the device selected in item 14. | Name of the objects of the selected type registered in the system | Name of specified system object | Depends on the number of objects of the selected type in the digital distributed video surveillance system. |
27 | Event | Select in the list | Specifies which event coming from selected devices is to be logged. NOTE. If the field is empty, the Event viewer displays all events coming from specified devices. | Names of event types for selected type of devices. | Not set | Depends on the type of object. |
28 | Region | Select in the list | Sets the region where the objects to log the events from are located. | Name of the region registered by the system. | Not set | Depends on the number of Region objects created in the digital distributed video surveillance system. |
29 | Color | Select in the list | Sets the messages highlight color in the Event Viewer | RGB, CMY or HSL. | White | Corresponds to the standard range of the selected color system. |