To configure a V2000 controller's auxiliary relays, use the setup panel of the relevant Aux relay (V2000) object. To find this object,go to the Settings dialog box, click the Hardware tab, select the relevant VertX V2000 NC/RI object, and browse its object subtree.

Image Modified

 

To configure an auxiliary relay:

  1. Go to the setup panel of the Aux relay (V2000) object.
    Image Modified
  2. In the Address drop-down list, select the relay's address (1).

    Note
    titleAttention!
    The relay's address is set automatically when the object tree is created. Changing the address may lead to losing the connection to the relay.
  3. In the Minimum time, msec field, enter a time period (in milliseconds). This is the minimum time during which the relay is on (2). The allowed value range is 25 milliseconds to27 minutes.
  4. Click Apply to save the changes (3).

...