Go to documentation repository
Page History
...
- Go to the Reader (V2000) object's setup panel.
- Select the position of the reader in the Position field (1).
- Select the type of reader used in the Reader type field (2).
- Set the access mode by selecting it from the corresponding drop-down list (3).
- Check the Reader I'm alive enabled box to enable the reader (4).
- Select the Report I'm alive message to the controller to send a notification to the controller about the connected reader (5).
- Select the time to send the message after connecting the reader in the Message time field (6).
- Select the message code in the I'm alive message field (7).
- Check the Reader accepts PIN commands box to enable the use of PIN-codes on the reader (8).
- Select the length of the PIN in the PIN length field (9).
- Select the number of attempts to enter the PIN in the Attempts field (10).
- Specify the digital code associated with the end of the PIN entry in the End of PIN code field (11).
- Specify the digital code associated with the clearing command of the entered PIN in the Clear code field (12).
- Select the keypad type from the drop-down list (13).
- Set the maximum time for entering the PIN in seconds in the Maximum time for entering PIN, sec field (14).
- Set the pause in seconds, during which the reader will not accept attempts to enter the code, if the limit of dialing attempts is exceeded (15).
- Select the mode for suppressing the PIN-schedule in the Card and PIN access mode in the Suppress PIN (Card and PIN) field (16).
- Select the type of asntipassback antipassback control in the APB type field (17).
- Set the time period for timed antipassback control in seconds (18).
- Select the action to take when the antipassback is registerd registered by setting the corresponding switch (19).
- Select the region which the user enters in the Enter field (20).
- Select the region from which the user enters in the Exit field (21).
- Click the Apply button to save the changes (22).
...
Overview
Content Tools