- Select the input address from the Number drop-down list (1).
- Set the Configured checkbox if the input is in working state (2).
- Set the Tamper is normally opened checkbox if it's required to receive alarm events while breaking or opening the sensor housing (3).
- Set the Sensor is normally opened checkbox if it's required that input is to be in normal state (not alarm) while opened contacts (4).
- To require disarming of input set the corresponding checkbox (5).
- In the Delay for entrance field enter the value in seconds defining time for input disarming (6).
- In the Delay for exit field enter the value in seconds defining time period during which the object can exit after the input arming (7).
- From the Mask by time zone drop-down list select the time zone during which events won't be generated for the input (8).
If necessary, assign the input with a term of an internal variable (9, see Associating AIO input with a term).
- Click the Apply button.
The AIO input is now configured.