Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Low-level protocol. The system developer presented events, reactions and equipment connection commands as the byte set, so the equipment can be directly connected to Intellect.
  2. SDK – Software Development Kit. The system developer presented SDK, so the equipment can be directly connected to Intellect.

  3. Communication server (Program-driver). The system developer presented own driver (program layer between ITV|AxxonSoft software and hardware in which events, reactions, configuration commands and state request are built in) in order to connect the equipment. Install the third-party software and configure its interaction with Intellect in order to connect the equipment to Intellect. COM-server and OPC-server are examples of such programs.
  4. SOFT-SOFT. The system developer enabled using its commands in Intellect and vice versa in order to connect the equipment. Install the full version of third-party software and configure its interaction with Intellect in order to connect the equipment to Intellect. Database synchronization is a way of SOFT-SOFT integration on the level of joint using of one database by two software packages, e.g. to access the event log.
  5. Universal protocol integration: OPC, SNMP and BACnet. OPC and BACnet are industry standards. The system developer makes OPS-server and BACnet-server implementation for its devices and sends data over OPC or BACnet protocols. Intellect is the client for such servers and it gets data (events, reactions, configuration commands, etc.). SNMP is a network protocol used to monitor some devices. The list of some hardware connected to Intellect over universal protocols is specified in the Systems connected by universal protocols section.

Integrated hardware

Info
titleNote

Documentation is available in English only for integration modules names of which are marked "*"  in the table as these modules are not included in the Russian version of ACFA Intellect installation package.

Info
titleNote

Restrictions (column 3 in the table) mean the following:

  • Monitoringintegration module allows only getting events - control and configuration of Intellect is not available.
  • Monitoring, control - integration module allows getting events as well as controlling objects on the map: arm/disarm alarm loops, commands to executive devices, etc. It is impossible to configure in Intellect.  
  • Monitoring, control, configuration - integration module allows doing any operations (equipment configuration, control, monitoring) using only Intellect.

Fire&Security Alarm (FSA) systems

...