Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

TheID field*

Automatically

Displays the identification number of the User permissions  object in the system

Sequence of numbers

-

Depends on the number of the User permissions  objects in the system.

2

The Name field*

Enter the value in the field

Sets the name of the User permissions  object in the system

Latin, Cyrillic and service characters

User permissions

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive.

Number of symbols – from 1 to 60.

3

The Disable checkbox

Set the checkbox

Defines the status of the User permissions  object (enabled or disabled) in the system

Boolean type

No

Yes – the User permissions object is disabled and is not in use.

No – the User permissions object is enabled and is in use.

The Configuration Configuring group

4

The group of Tabs* checkboxes

Set the checkbox

Specifies the tabs of the System settings dialog box that can be accessed when the User gets the corresponding rights

Boolean type

All checkboxes are set unchecked

The following values are available for each tab:

Yes – User is allowed to manage the objects in the tab.

No – access to the tab is forbidden.

5

The Ask User Password for Shutdown Systemuser password for shutdown system checkbox

Set the checkbox

Allows shutting down Intellect using the password of the authorized User

Boolean type

No

Yes – User with these rights is allowed to shut down Intellect

No – User with these rights is not allowed to shut down Intellect

6

The Ask Administrator Password for Shutdown Systemadministrator password for system shutdowncheckbox

Set the checkbox

Allows shutting down Intellect using the password of the Administartor

Boolean type

No

Yes – Intellect shuts down onlywhen the Administrator password is in use

No - Intellect shuts down in various ways

7

The Forbid to hide interface checkbox

Set the checkbox

Allows hiding interfaces in Intellect

Boolean type

No

Yes – interfaces cannot be hidden

No – interfaces can be hidden

8

The Reloginprohibited checkbox

Set the checkbox

Allows changing the user in Intellect

Boolean type

No

Yes – User can be changed

No – User cannot be changed

9

The list of system objects*

Automatically

Displays the objects created in the system and allows setting the administration and monitoring rights

-

-

-

The Access to archive group

10

The Depth __ last hours field

Enter the value in the field

Sets the number of last hours of video archive that can be viewed

Nonnegative integer

-

>=0

0 means that viewing the archive is prohibited  

11

The Since last access checkbox

Set the checkbox

Sets the time to define the archive depth

 

Boolean type

No

Yes – hoursavailable for viewingare counted since the User logged in

No - hoursavailable for viewingare counted from since the current timemoment

The Access to backup archive group

12

The Depth __ last hours field

Enter the value in the field

Sets the number of last hours of backup archive that can be viewed

Nonnegative integer

-

>=0

0 means that viewing the backup archive is prohibited 

13

The Since last accesscheckbox

Set the checkbox

Sets the time to define the backup archive depth

Boolean type

No

Yes – hoursavailable for viewingare counted since the User logged in

No - hoursavailable for viewingare counted from since the current timemoment

No group

14

The Allow to remove video archive files remove checkbox

Set the checkbox

Defines whether video archive files can be removed from  the Monitor interface

Boolean type

No

Yes – The “Remove video from the feature menu” item is available in the Monitor

No – removing video from the feature menu is not available

15The Allow rewrite protection checkboxSet the checkboxSets possibility of rewrite protecting of filesBoolean typeYes

Yes – operator added to these permissions can protect archive records against loop recording

NoOperator can't operator cannot protect archive records against loop recording
16The Allow to disable file protection checkboxSet the checkboxSets possibility to disable rewrite protection of filesBoolean typeYes

Yes – operator added to these permissions can reset rewrite protection of files

No – Operator can't reset rewrite protection of files
17The Allow export checkboxSet the checkboxSets possibility to export protected recordsBoolean typeYes

Yes – Operator added to these permissions can export video recordings.

No – Operator cannot export video recordings.
18The Terminate session when inactive __ minutes checkbox and field
Set the checkbox, enter the value in the field

Sets the time period (in minutes) when the operator is inactive - at the end of this period the session is to be terminated

Boolean type, integerNo

Да – when the operator is inactive for the specified time period, session is not automatically terminated. To continue operation, log in the system specifying the username and password. 

Нет – session is not automatically terminated when the operator is inactive.

19The ONVIF dropdown list
Select the value in the listSets user permissions to use the ONVIF ServerSupported types of permissions-

Administrator

Operator

User

20The Permission import button
Click the buttonSets possibility to import user permissions to use the ONVIF Server---

* The name of the object is not displayed on the settings panel