titleNote.

When moving configuration to the Backup Server and getting it back to the Main Server the Failover service object generates START and STOP events. These events can be used in scripts for flexible system configuration. For examples see Examples of scripts in JScript language section of Programming Guide (JScript).

...

The Failover mode is configured using the Failover service objects created under the Computer objects corresponding to backup servers in the Hardware tab of the System settings dialog box.

...

If the quantity of cameras is bound to specific Servers in the protection key, then the license becomes invalid when cameras are moved to the backup Server. In this case the system gives 2 months to restore the faulty Server in order to move the cameras back and the license to become valid again. Otherwise, Intellect will unload on the backup Server because the hardware limit is exceeded (see Features of the Intellect software operation when the object limit is exceeded section). Time (in days) remaining for restoring the main Server is shown on the settings panel of the Failover service object:

When you log off INTELLECT™, configuration is not transferred from main Server to a standby server.

The number of failovers running simultaneously can be limited. For this the Manager of Failover managerservices object is used. It is created under any LOCALHOST object (that is not a Client) in the system – see Role-assignment in distributed system section). Only one one Manager of Failover managerservices object can be created in the system.

...