Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Information on disk failures (the Disk failure alarm type) and its re storing is updated in the following cases:
    1. at ATM-Intellect Pro startup and then every 15 minutes.
    2. at receiving local message SLAVE|NO_DISC (No disk for archive storage) from Intellect core.
    3. at receiving local message DISC_EXIST (Disk for archive storage found) from Intellect core.
    4. at receiving local message DISC_UNMOUNT (Disk unmounted) from Intellect core.
    5. at receiving local message DISC_MOUNT (Disk mounted) from Intellect core.
  2. Information on archive size (the Archive size too small alarm type) is updated at ATM-Intellect Pro startup and then every 15 minutes.
  3. Information on the computer normal and abnormal  restarts is displayed in the interface in 5 minutes.
  4. Information on free disk space is updated every 1 hour.
  5. ATM-Intellect Pro initiates the connection with ATM-Intellect Workstation and once in a ping period (2 minutes by default) sends a package with technical data to the ATM-Intellect Workstation. If ATM-Intellect Workstation have not been receiving any data from ATM-Intellect Pro within 6 minutes, the “No connection” error is displayed for such object.
  6. The Video.run process status (hangup) is checked at startup of Videosrv.exe module and then every 15 minutes, and besides that each time the  Videosrv.exe module reconnects with the Intellect software, i.e. if the Intellect software was shut down and started again. 
  7. Availability of running processes "Intellect.exe" and "Video.run" is checked every 10 seconds.