- Open the intellect.ddi file in the ddi.exe utility.
- Select the CAM object.
- Go to the Events tab.
- Set the Do not record and Do not send to the network checkboxes checked for the MD_START (Alarm) and MD_STOP (Alarm end) events.
Save the file.
Update the database using the idb.exe utility (the Update database button, see Interface elements of the idb.exe window).
...