№ | Name | Field type | Description | Format | Default value | Value range |
Settings group | ||||||
1 | State | Select from drop-down list, or type in | The message to display during macro execution. A Standard value is selected, no message is displayed. | - | Empty | A list of available messages plus Standard. |
2 | Local | Checkbox | If the checkbox is checked, the macro can be executed on the local computer only. Note. This checkbox does not apply to Hide and Show reactions of any Display. Regardless of the checkbox, wen called from Server/RAW, they are executed on the Server and all connected Clients; when called on Client, they are executed only on the client. | - | No | Checked - local only. Unchecked – any computer. |
3 | Hidden | Checkbox | If the checkbox is checked, the macro cannot be executed manually. | - | No | Checked – execute. Unchecked – don’t execute. |
4 | Events table | |||||
Type | Drop-down list | Defines the object to be the source of the event that will trigger this macro. | - | Empty | All active device and module objects | |
5 | Number | Drop-down list | Defines the number of the object to be the source of the event that will trigger this macro. | - | Empty | The numbers of all active device and module objects. If the Computer object is selected in the Type column, enter its name here. |
6 | Name | Enters automatically on right-click | Information type | - | Empty | Enters automatically according to the Type and Number values |
7 | Event | Drop-down list | Event type | - | Empty | The list of registered event types |
Parameters table (is set, when parameter should be set for events, selected in Events table) | ||||||
8 | Name | Automatically | Displays name of event’s parameter | Latin alphabet, digits and characters | Empty | Depends on the event, selected in Events table |
9 | Value | Entering of the text into the field | Set the value of event’s parameter | Latin alphabet, digits and characters | Empty | A line of any characters. The number of characters is from 1 to 250. |
| Actions table | |||||
10 | Type | Drop-down list | Defines the object to be the source of the event that will trigger this macro. | - | Empty | All active devices and module objects |
11 | Number | Drop-down list | Defines the number of the object to be the source of the event that will trigger this macro. | - | Empty | The numbers of all active devices and module objects. If the Computer object is selected in the Type column, enter its name here. |
12 | Name | Automatically | Displays name of the selected object | Name of objects, registered in the system and of specified type | Empty | A line of any characters. The number of characters is from 1 to 60.
|
13 | Action | Drop-down list | Reaction to be executed for the selected object when the event is registered | - | Empty | The list of registered reaction types for the selected object type |
Parameters table (is set, when parameter should be set to perform action, selected in Actions table) | ||||||
14 | Name | Automatically | Displays name of action’s parameter | Latin alphabet, digits and characters | Empty | Depends on the action, selected in Actions table |
15 | Value | Entering of the text into the field | Set the value of action’s parameter | Latin alphabet, digits and characters | Empty | A line of any characters. The number of characters is from 1 to 250.
|
Outside the groups | ||||||
16 | Response sending delay (sec) | Entering of the value into the field | Sets time period (in seconds) that must pass after events specified in the Events column occur and before executing reactions specified in the Actions column. Note. If the events reoccur before the specified time period expires, the reaction execution wait period is prolonged, i.e. reactions will be executed only once when events do not reoccur over the specified period. | Integer number | - | >0 |
17 | The Fast call field | Left-click in the field and click the required key combination | Sets a shortcut for a macro. Note. If the same combination of hot keys is set for several macros, when clicking a key combination, all of these macros run. | Key combinations | No | Some keys of the main or numeric keyboard, as well as these keys in combination with Shift, Ctrl and Alt. |
18 | The Icon type dropdown list | Select in the dropdown list. | Sets a set of icons for displaying a macro on the map. Note. Changing the icon appearance will take effect after restarting the map interface. To restart the interface, restart Intellect or log in once again under the corresponding Operator account. | Available icon appearances on the map | - | Macro 1 - Macro 7, empty value. |
...