Go to the Time and Attendance object’s settings panel. It is located on the Interfaces tab of the System Settings dialog window.
Info title Note. In the ver. field the current module version is displayed (7)(8). - Set the Fix position checkbox to fix the Time and Attendance module interface window in the specified desktop coordinates (1).
- From the Monitor drop-down menu (2), select the monitor on which the Time and Attendance module interface window should be displayed, if the Fix position checkbox is set.
- To configure the position of the Time and Attendance software module’s module interface window, specify the coordinates of the window’s upper left corner in the X: and Y: fields and its width and height in the W: and H: fields (2).Set the Fix position checkbox if the module’s window is to be kept in the specified coordinates on the desktop (13).
- In the 9 field check department that should be available in the Time and Attendance module (9).In the Permissions settings field configure Permissions settings field (4), the rights for operator working with the client part of the Time and Attendance module (3)are configured.
From the Departments and users drop-down list menu, select the operator access level to the Departments navigation panel (3).
Access level
Description
Editing
Full access, editing is available
ViewingAccess without editing
Read-only access
Forbidden
No access
- From the Schedules drop-down list select the operator access level to the Schedules navigation panel (3).
- From the Documents drop-down list select the operator access level to the Documents navigation panel (3).
- From the Reports drop-down list select the operator access level to the Reports navigation panel (3).
- In the Archive size: field field specify the size of the events archive in days (45).
- Set the Add departments dynamically checkbox to automatically add all departments created in the Visitor Management System module to the Time and Attendance module (56).
- In the Report Server address: field field specify the address of the reports subsystem server (67).
- In the 7 field enter the connection string to the database (7the field 9 select the departments that should be available in the Time and Attendance module (9).
- Click the the Data source button button to select the database source (10).
- In the opened Data link properties dialog box on the Data provider tab select the data source (SQL Server).
On the Connection tab, from the Select the name of SQL server from the 1. Select or enter a server name line on the Connection drop-down menu (1), select the required SQL server.
Info title Note. Selecting the way of authorization on the MS SQL server is described in the Error! Reference source not found. Operational architecture schemes available for some service modules section. - Select the required database from the From the Select the database on the server: drop drop-down list menu (2), select the required database.
- To save changes click OK button.
- In the opened Data link properties dialog box on the Data provider tab select the data source (SQL Server).
- Click Apply button to save changes.
This completes the process of configuring the The Time and Attendance software module object is configured.