- Go to the ATM Monitoring settings panel.
- If it is necessary to display the Owner Panel component on the screen, select the Owner Panel check box and specify the component coordinates the on-screen coordinates of the component (1).
- If the Control panel displaying is needed, set the Control panel checkbox and specify its coordinates on the screen (2).
- If the Log panel displaying is needed, set the Log panel checkbox and specify its coordinates on the screen (3).
- The setting Non-empty comment field is used if the operator is required to comment on the alarm and/or their actions when the alarm is accepted (4). This comment is available for viewing in the event log as well as the name of the operator who accepted the alarm.
- By default, objects can be filtered by Alarm and Failure events as well as by Connected and Disconnected states on the Control Panel. Uncheck the Use filter by events box to disable this feature (5). As a result, the corresponding drop-down list becomes disabled on the Control Panel.
If when live video is attempted to be viewed from Control Panel it is necessary to display a warning that it can create the critical load per channel, set the Warning when watching live video checkbox (6).
Info title Note. This setting is not available for ATM-Intellect Workstation TC installation type. - If ATM-Intellect Pros and Additional workplaces are in different subnets and the ATM-Intellect components are not in a distributed system configuration in Intellect object tree and Data gateway is in use for transmission of live video to Additional workplaces, set the Viewing live video through gateway checkbox (7).
In the Speed of video stream field specify the frame rate for live video displaying in frames per second (8). This parameter is used to limit the flow of data between the ATM Intellect Workstation and the ATM Intellect Pro (for example, in the case of low-bandwidth communication channel) while viewing live video from the objects through the ATM Monitoring window (see document ATM Intellect. Operator's guide).
Info title Note. This setting is not available for ATM-Intellect Workstation TC installation type. - Select the required compression rate for the live video in the Compression drop-down list (9).
- Select groups of alarms for the Control panel and the Log panel to be displayed (10).
If specific owners are to be available for specific users on the Owner Panel, then set the filter by owners:
- Click the Filter… button (8).
The Filter by owners window appears. The list of available user-owner pairs is on the left, the list of selected ones is on the right.
Info title Note. The list of owners is set on the Control Panel – see Reference information section of Operator's Guide. - Users and their rights are configured in the Users tab of the System settings dialog box – get information on how to do it in the Intellect Software Package. Administrator’s Guide. The latest version of this document can be found in AxxonSoft documentation repository.
- Move the pairs between the lists using the <- and ->buttons.
- When the list of user-owner pairs is formed, click the Apply changes and close button.