  1. Create the VideoIntellect Detection Tool object on the basis of the Camera object on the Hardware tab of the System Settings dialog box (1).
    Image RemovedImage Added
  2. From the VideoIntellect Client ID drop-down list (2), select the VideoIntellect Client object identifier used to connect to the VideoIntellect software .
  3. In order to receive the triggerings from the camera that is not configured in the Intellect, in the Object ID in VideoIntellect system  field (3), enter the video analytics detector identifier in the VideoIntellect software terms. The identifier should be entered in the following format: {4f4dfe1d-7109-44fd-8a6f-8d40ea198710}.
  4. If it is necessary to generate an alarm on the camera when receiving a detector triggering, set the Display objects checkbox (4).
  5. In the Alarm timeout, ms field (5), enter the time period in millisecond after which the Intellect alarm will be forcibly terminated, even if the corresponding message to terminate the alarm has not been received from the VideoIntellect software.
  6. Click Apply (6).

...