Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The AxxonPlayer.exe utility can be used to access the archive created by a standby Server on NAS or local drive (see Viewing video using the The Axxon Player utility sectionfor viewing and converting the video archive). Alternatively, main and backup server archives can be synchronized through the Backup archive module (see Configuring archive synchronization of main and backup Servers).

...

The Failover mode is configured using the Failover service objects created under the Computer objects corresponding to backup servers in the Hardware tab of the System settings dialog box.

Image RemovedImage Added

If the quantity of cameras is bound to specific Servers in the license key, then the license becomes invalid when cameras are moved to the backup Server. In this case the system gives 50 days to restore the faulty Server in order to move the cameras back and the license to become valid again. Otherwise, Intellect will unload on the backup Server because the hardware limit is exceeded (see Features of the Intellect software operation when the object limit is exceeded section). Time (in days) remaining for restoring the main Server is shown on the settings panel of the Failover service object:

...

If the number of dead servers exceeds the limit specified for the backup Server, configuration from new dead servers will be transferred to the corresponding backup Server as previously dead servers restore.