№ | Parameter | Method for specifying the parameter | Parameter description | Symbol | Default value | Range of values |
---|---|---|---|---|---|---|
1 | The Identification number field | Automatically | Shows the identification number of the Display managerobject in the system | Sequence of numbers | - | Depends on the number of Display managerobjects in the system |
2 | The Name field | Type-in the value in the field | Assigns the name to the Display manager object | Latin, Cyrillic and service characters | Display manager | A line containing a sequence of any symbols (letters, digits, service, characters apart from > and < symbols), non case-sensitive Number of symbols – from 1 to 60 |
3 | The Disable checkbox | Set the chechbox | Shows the status (enabled or disabled) of the Display manager object in the system
| Boolean type | No | Yes – the Display managerobject is disabled and is not in use No – the Display manager object is enabled and is in use |
4 | The Display dropdown list | Select from the list | Assigns the parent Display object , to which the given Operator protocol Display manager object refers | Name of the Display objects registered in the system | Name of the parent Display object | Depends on the number of the Display objects in the system |
5
| The X filed | Type-in the value in the field | Sets the coordinate in the X horizontal axis for the upper left corner of the Display manager interface object on the screen | % of the screen width | - | From 0 to M*100, where M is the number of monitors installed |
6 | The Y field | Type-in the value in the field | Sets the coordinate in the Y vertical axis for the upper left corner of the Display manager interface object on the screen | % of the screen height | - | From 0 to M*100, where M is the number of monitors installed |
7 | The W filed | Type-in the value in the field | Sets the window width of the Display manager interface object | % of the screen width | - | From 0 to M*100, where M is the number of monitors installed |
8 | The H field | Type-in the value in the field | Sets the window height of the Display manager interface object | % of the screen height | - | From 0 to M*100, where M is the number of monitors installed |
9 | The X button | Click the button | Opens the window for automated setting of the X, Y, W and H parameters | - | - | - |
10 | The Monitor dropdown list | Select in the list | Sets the system ID of the monitor for which the coordinates are set | IDs of the monitors in the OS | 1 | From 1 to 16 |
11 | The Allow moving checkbox | Chechbox is set | Allows hand shifting of the Operator protocol Display manager interface box | Boolean type | No | Yes – hand shifting is allowed. No – hand shifting is prohibited. |
12 | The Available PCs field | The >, <, >>, << buttons | Contains a list of Computer objects that have not yet been selected to be managed via the Display manager | Names of the Computer objects registered in the system | Depends on the number of Computerobjects in the system | Depends on the number of the Computer objects in the system |
13 | The >, <, >>, << buttons | Click the button | Moving computers from the Available PCs list to the Selected PCs list and vice versa | - | - | - |
14 | The Selected PCs field | The >, <, >>, << buttons | Contains a list of Computer objects that are selected to be managed via the Display manager | Names of the Computer objects registered in the system | - | Depends on the number of the Computer objects in the system |
15 | The Selection of cameras dropdown list | Select in the list | Specifies the cameras sorting method in the Display manager interface | Available sorting methods | By number | By number By name |
...