No | Parameter name | Field type | Description | Representation | Default value | Value range |
1 | The Core IP address field with button. Is set on the Client | Type-in the value in the field/use the button | Set the IP address of the Intellect server to which the slave.exe module is connected by default.
| IP address | 127.0.0.1 | Depends on net settings of the Server. In case of connection failure dialog window requiring IP address is displayed |
2 | The Keyboard prefix field | Type-in the value in the field | Set the prefix for a special key-board. When a button is pressed on this key-board the Intellect detects when the button was pressed on this very key-board | Symbol | - | Usually, a tilde (~), code 126 |
The Logging subsystem group | ||||||
3 | The Debug mode dropdown list | Drop-down list item | Set the mode of the Intellect Debug window displaying
| List of available modes of Debug window displaying | None
| Disabled – Debug window is not displayed. Debug 1 – Debug window is displayed and a log-file containing recordings about modules errors is created. Debug 2 – Debug window is displayed and a log-file containing recordings about modules errors and alerts is created. Debug 3 – Debug window is displayed and a log-file containing recordings about all the modules events is created. Debug 4 – Debug window is displayed and a log-file containing recordings about all the modules events, and also additional menu that is individual for each module (used by programmers) are created. |
4 | The Log-storing time (hours) field | Type-in the value in the field | Set the time of keeping log files | Sequence | 48 hours | > 0 |
5 | The Counters logging time (sec) field | Type-in the value in the field | Assigns the time interval in seconds for logging processor load, memory usage, and disk usage. | Sequence | 60 | Positive whole numbers not less than 60 and zero. If the value 0 is specified, sensor data is not included in the log file. |
6 | The Save logs checkbox | Checkbox | Enables logs saving | Boolean type | Yes | Yes – logs are saved. No – logs are not saved. |
7 | The Redirect to debugger checkbox | Checkbox | Enables the debugger | Boolean type | None | Yes –the debugger is in use. No – the debugger is not in use. |
8 | The Maximum size (MB) field | Type-in the value in the field | Defines the maximum size of RAM that log files can use. Log files are archived after that size is reached. | Sequence | 100 MB | >= 100 Values less than 100 Mb are ignored. |
The JPG and AVI files export path group | ||||||
9 | The Default (Intellect\Exp-ort)/Other switch | Set in the position | Set the folder for exported files from Intellect video archive
| - | Default (Intellect\Export)
| Default (Intellect\Export) – exported to the C:\Users\%current user name%\Documents\Intellect\export\ folder Other – exported to the selected folder |
10 | The Other field with the button | Click the button/type-in the value in the field | Set the pathname to the folder, where files from video archive are to be exported when the switch is set in the Other position | Pathname | - | - |
11 | The Open folder button | Click the button | Opens the current folder to export the files | - | - | - |
12 | The Record path checkbox | Checkbox | The checkbox forbids export catalogue change while exporting the archive period as well as exporting the archive from AviExport utility. | Boolean type | No | Yes – export catalogue change is forbidden. No – export catalogue change is allowed. |
No group | ||||||
13 | The Receive uncompressed video checkbox | Checkbox | Enables receiving uncompressed video from the Server. As a rule is set on the Client | Boolean type | No | Yes – Client receives uncompressed video from the Server No – Client receives compressed video from the Server
|
14 | The Event viewer over all windows checkbox | Checkbox | Enable displaying the Event viewer window over all windows. | Boolean type | No | Yes – the Event viewer window is displayed over all windows. No – the Event viewer window is displayed if a corresponding screen is selected |
15 | The Only local protocol checkbox | Checkbox | Enables logging the events registered in the given computer to the Events protocol database. Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section. | Boolean type | No | Yes – events registered in the given computer are recorded to the Events protocol database No – all required events are recorded to the Events protocol database
|
16 | The Disable protocol checkbox | Checkbox | Disables events logging to the Event viewer database on this computer. Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section. | Boolean type | No | Yes – events are not logged to the Event viewer database No – events are logged to the Event viewer database
|
17 | The Used memory dump checkbox | Checkbox | Enables logging .dmp file with a copy of main memory with incorrect shutting down at least one of the system modules to the Intellect root folder | Boolean type | No | Yes – memory dump is created No – memory dump is not created |
18 | The Support old scripts checkbox | Checkbox | Set the support of program tools in Intellect | Boolean type | No | Yes – both scripts and programs are supported No – only scripts are supported
|
19 | The Time synchronization checkbox | Checkbox | Set time synchronization of all computers in the distributed system with system time of this computer. Time is automatically synchronized at midnight every 24 hours or when INTELLECT™ is started on the Server that is the source of time synchronization. | Boolean type | No | Yes – synchronization is enabled No – synchronization is disabled
|
20 | The Overlay in Event viewer protocol dropdown list | Drop-down list item | Set the overlay mode for processing the video signals that can be viewed with the help of the Event viewer protocol object | Names of overlay modes | Overlay 2 | None – video signals are not processed by video card Overlay 1 – video signals are processed as a single video streamDirect3D is used Overlay 2 – video signals are processed independently from each otherDirectDraw is used |
21 | The Application language dropdown list | Drop-down list item | Assigns the Intellect Software System's interface language | Names of installed languages | - | Depends on the set of installed languages. The process of installing languages is described in Intellect Software System's interface language. |
...