Description of the ATM Monitoring object settings panel elements is given in the table.
# | Parameter | Method for setting the parameter value | Description | Type | Default value | Value range |
1 | Identifier | Automatically | Shows the identification number of the ATM Monitoring reports object in the system | Nonnegative integer | - | >=0 |
2 | Parameter | Enter the value in the field | Shows the name of the ATM Monitoring object in the system | Latin, Cyrillic letters and service characters | ATM Monitoring | A line representing a sequence of any symbols Number of symbols – from 1 to 60. |
3 | Display | Is selected in the list | Assigns the parent Display object for the ATM Monitoring object | Names of Display objects registered in the system | Name of the parent Display object | Depends on the number of the Display objects in the system. |
4 | Owners panel | Is set in a checkbox | Enables Owners panel displaying | Boolean | True | True - Owners panel is displayed False - Owners panel is hidden |
5 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the Owners panel interface box | % of the screen width | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
6 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the Owners panel interface box | % of the screen width | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
7 | W: | Enter the value in the field | Set the width of the Owners panel interface box | % of the screen width | 100 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
8 | H: | Enter the value in the field | Set the height of the Owners panel interface box | % of the screen width | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
9 | Control panel | Is set in a checkbox | Enables Control panel displaying | Boolean | True | True - Control panel is displayed False - Control panel is hidden |
10 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the Control panel interface box | % of the screen width | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
11 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the Control panel interface box | % of the screen height | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
12 | W: | Enter the value in the field | Set the width of the Control panel interface box | % of the screen width | 100 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
13 | H: | Enter the value in the field | Set the height of the Control panel interface box | % of the screen height | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
14 | Log panel | Is set in a checkbox | Enables Log panel displaying | Boolean | True | True - Log panel is displayed False - Log panel is hidden |
15 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the Log panel interface box | % of the screen width | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
16 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the Log panel interface box | % of the screen height | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
17 | W: | Enter the value in the field | Set the width of the Log panel interface box | % of the screen width | 100 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
18 | H: | Enter the value in the field | Set the height of the Log panel interface box | % of the screen width | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
19 | Non-empty Comment field | Is set in a checkbox | Is set to require that operators leave comments when accepting an alarm to describe the alarm and/or their actions | Boolean | True | True - Comment field shall not be empty on alarm accepting False - alarm accepting can be done without a comment from Operator |
20 | Use filter by events | Is set in a checkbox | Is set to enable filtering objects by Alarm and Failure events and Connected and Disconnected states |
. | Boolean | True | True – filter can be applied. False – filter cannot be applied. |
21 | Warning when watching live video | Is set in a checkbox | Is set if |
it is necessary to display a warning upon the live video playback attempt that it can create the critical load |
on the data channel. Attention! This setting is not available at the ATM-Intellect Workstation TC | Boolean | True | True - when live video is attempted to be viewed from Control Panel the warning is displayed False - when live video is attempted to be viewed from Control Panel the video is displayed with no warnings | |||
22 | Viewing live video through gateway | Is set in a checkbox | If set if ATM-Intellect Pros and Additional workplaces are in different subnets and the ATM-Intellect components are not in a distributed system configuration in Intellect object tree and Data gateway is in use for transmission of live video to Additional workplaces | Boolean | False | True – live video is transferred to the Additional workplaces through the data gateway. False – live video is transferred to the Additional workplaces directly from the ATM-Intellect Pro. |
23 | Viewing live video from all cameras (add.) | Is set in a checkbox | Is set if the "All cameras of Surveillance Object" item should be added to the object's "Video image playback" context menu |
which enables viewing video from all cameras of the selected Surveillance Object. | Boolean | False | True – the "All cameras of Surveillance Object" item is added to the object's "Video image playback" context menu on the Control Panel. False – there is no "All cameras of Surveillance Object" item in the menu. |
24 | Video stream speed | Enter the value in the field | Sets |
the number of frames per second of the video image when viewing live video or video from the archive.
|
|
| Frames per second | 25 | Depends on the camera features | |||
25 | Compression | Is selected in the list | Sets the compression rate for the live video. | Available compression rates | False | 0-5 |
26 | Groups of alarms | Is set in a checkbox | Sets alarms that one want to visualize on the Control panel | Boolean | All checkboxes except the Temperature sensors are set | If checkbox is set next to the group of alarms, then alarm from the corresponding group will be displayed on the Control panel |
27 | Filter by owners | Via the Filters... button | Displays selected pairs of users and owners | - | - | - |