Setting up Arena program module is performed in the following way:
- Go to the Hardware tab in the System setting dialog window (1).Select the Arena module object , corresponding to the set up Arena program module on the Hardware tab (2). The settings panel of the selected object will open on the right side of the windowsettings panel, which is created on the basis of the LPR Channel object (2).
- In the IP address field enter the IP-address of the Arena computer with installed ftp-server (3).
- In the FTP Port field enter the port for connection to the ftp-server (3). Port 21 is used by default.
- In the TCP/IP Port field enter the TCP/IP port for connection to the ftp-server (3). Port 6008 is used by default.
- In the Login and Password Login (4) and Password (5) fields enter the user name and password for connection to this ftp-server (4-5).
- In the Frames polling interval, ms field enter the time between two one by one requires of Auto-Intellect PC for downloading the photos from the Arena integrated circuit (6).
- In the Alarm on speed limit, km/h field enter the maximum available vehicle speed in km/h (7). In case, when the vehicle moves at a speed above the maximum available vehicle speed, the system generates the report about the excessive speed.
- Click Apply (8).
...