  1. Go to the Synchronization parameter group on the settings panel of the Sphinx server object.
    Image RemovedImage Added

    Note
    titleImportant!
    The Dynamic sending checkbox is always to be checked for proper operation of Sphinx integration module (5).


  2. Parameters are to be auto synchronized between Intellect and Sphinx servers. Specify the interval for parameters auto synchronization (in hours) in the Synchronization interval field (1).
  3. To read Sphinx ACS configuration stored on Sphinx server click the Hardware synchronization button (2).
  4. To send ACFA Intellect configuration to Sphinx server click the Save configuration button(3).

    Note
    titleImportant!
    This action is to be performed after configuring interaction between Intellect and Sphinx servers.


    Info
    titleNote

    In order to speed up the autosync process, the following user sending logic is used.

    The users who have at the time of synchronization:

    1. the card issue date, which has not yet arrived;
    2. the card expiration date that has already passed;
    3. access levels that are unrelated to the the controllers of this Castle server;
    4. or the User locked property

    are not written to the controller.


  5. To clear the Sphinx server database click the Clear DB button (4).