- Go to the settings panel of the LPR channel object corresponding to the activated software module (see Activating the program module, used for identifying the plates).
- Enter the value in the Area search threshold field (1).
Set the Max. width and Max. height parameters:
4.1 Click the (2) button next to the parameters. Interactive interface of setting up the zone parameters showing the image from the corresponding camera will be displayed.
4.2 At the appropriate moment, click the Stop video button and then hold the mouse while dragging it across the required area and click OK button.Info title Note. You can select the zone in the Real Time Video mode as well.
Results of setting the parameters will be automatically entered in the Max. width and Max. height fields.
- Set the Min. width and Min. height parameters by analogy with Max. width and Max. height parameters using the button (3).
If necessary set the Skip unrecognized LPs checkbox (4).
Info title Note. This setting is only available for the Auto-URAGAN program modulesmodule.
If necessary set the Cut image with vehicle checkbox (5).
Info title Note. Setting up the frame with a car cut is used only in case of working with megapixel video surveillance cameras.
Info title Note. Setting up the frame with a car cut is available also with the use of Seenaptec program VIT program module.
- Click Apply button (8).
...