- Go to the settings panel of the AC ZK Controller C3-100 object.
- From the Gate: drop-down list select the type of controller connection: via Ethernet or RS-485 standard (1).
- In the Password: field enter the password for controller connection (2).
- In the IP: field enter the IP-address of the controller (3).
From the Anti-passback: drop-down list select the mode of anti-passback operation (4):
Mode
Description
Controller
Disable
The anti-passback function is disabled All controllers Readers of Door 1 The anti-passback function is enabled between the readers of Door 1 ZK C3-100, ZK C3-200 Readers of Door 2 The anti-passback function is enabled between the readers of Door 2 ZK C3-200 Readers of door 1, readers of door 2 The anti-passback function is enabled between the readers of Door 1 and Door 2 respectively ZK C3-200 Door 1 and 2 The anti-passback function is enabled between the readers of Door 1 and Door 2 ZK C3-200, ZK C3-400 Doors 3 and 4 The anti-passback function is enabled between the readers of Door 3 and Door 4 ZK C3-400 Doors 1 and 2, doors 3 and 4 The anti-passback function is enabled between the readers of Door 1, Door 2, Door 3 and Door 4 ZK C3-400 Doors 1, 2 and doors 3, 4
The anti-passback is enabled between Door 1, 2 and Door 3, 4 ZK C3-400 Door 1 and doors 2, 3 The anti-passback is enabled between Door 1 and Door 2, 3 ZK C3-400 Door 1 and doors 2, 3, 4 The anti-passback is enabled between Door 1 and Door 2, 3, 4 ZK C3-400 From the Interlock: drop-down list select the mode of doors interlocking (5):
Mode
Description
Controller
Disable
The interlock function is disabled All controllers Door 1 and 2 Doors 1 and 2 are interlocked mutually ZK C3-200, ZK C3-400 Door 3 and 4 Door 3 and door 4 are interlocked mutually ZK C3-400 Doors 1, 2 and 4 Door 1, door 2 and door 4 are interlocked mutually ZK C3-400 Doors 1 and 2, doors 3 and 4
Door 1 and door 2 are interlocked mutually, door 3 and door 4 are interlocked mutually ZK C3-400 Doors 1, 2, 3 and 4 Door 1, door 2, door 3 and door 4 are interlocked mutually ZK C3-400 - From the Backup period: drop-down list select the time interval in minutes for saving the database backup (6).
Set the Watch dog checkbox to activate the control mode (7).
Info title Note. The version of firmware and serial number of controller will automatically display in the corresponding fields while connecting the controller (8).
- Click the Apply button (9).
...