Configuring the SIP-device

...

Configuring the SIP-device connection to Intellect is complete.

Configuring the

...

tone DTMF commands

The setting of sending tone messages to a SIP Configuring the SIP-device relay is necessary for tone dialing the SIP- device (for example, sending the tone combinations a combination for opening a door) is carried out by setting the relay.

The SIP-device relays are configured in the following order:

  1. Go to the Relay tab on the settings panel of the SIP-device object (1).
    Image Modified
  2. Set the Signal type switch to SIP INFO (2).
  3. Select the type from the DTMF type drop-down list (2):
    1. in_bound – the signal is transmitted as normal sound in an audio stream.
    2. rtp_nte  signals are transmitted via RTP separately from the voice stream.
    3. sip_info  signals are transmitted in the SIP INFO message.
    4. sip_info_relay  signals are transmitted in the SIP INFO message with the DTMF Relay function.
    5. sip_notify  signals are transmitted in the SIP NOTIFY message.
  4. In the Signal duration, ms field set the time period in milliseconds during wich the command is to be sent(3). This value is applied if duration is not set for a specific command.
  5. In the Name field, enter tha name of the command displayed on the SIP panel (4).
  6. In the Code field, enter the unique command code (5).
  7. In the Duration, ms field, enter the time period in milliseconds during which the command is to be sent (6In the Parameters field (3), specify the set of the command characters. See the command example for opening the door:
    Signal=1*1#
    Duration=250
    
    Signal=*22*
    Duration=250
    
    Signal=dro
    Duration=250
    where Signal is the sending code (unique for all devices),
    and Duration is the signal duration (recommended value is 250).
  8. Click Apply (47).
  9. The corresponding Relay object (58) will be created in the Intellect hardware tree.

...