Go to documentation repository
Page History
...
- Go to the Search by alarms tab.
- Repeat steps 2-12 of the section Forming the search query by events as applied to interface elements of the tab Search by alarms (1).
In the group External DB (2) set the checkboxes for those external databases, which events have to be returned in search query results.
Info title Note. This setting is enabled if the checkbox Plate number is found in the DB is set in the Alarm type group (9).
Info title Note. The External database group contains a list of all the databases that have ever been used together with the Vehicle Tracker module but, by default, databases removed from the Intellect software package are not displayed in the list. Select the Show deleted in the View menu of Event search in the Recognizers DBs main window to search by removed servers of plate recognizers. As a result, all external databases removed from the system will be displayed in the list. Set checkboxes for those databases which will be used while being searched.
From the Permitted speed list (3) select the required speed filter, permitted on the controlled road area and then in the activated field(s) (4) enter the threshold speed value(s) in km/h.
The following filters of the permitted speed are available:
4.1 No matter – events of the vehicle, registered on the road area with any permitted speed will be returned.
4.2 More – events of the vehicle, registered on the road area with any permitted speed, exceeding the entered threshold value will be returned.
4.3 Less – events of the vehicle, registered on the road area with any permitted speed, not exceeding the entered threshold value will be returned.
4.4 Interval – events of the vehicle, registered on the road area with any permitted speed, that belong to the entered threshold value range will be returned.
From the list Alarm handling delay, sec (5) select the required filter according to the alarm handling delay and then in the activated field(s) (6) enter the threshold value(s) of delay time in seconds.
The following filters of alarm handling delay are available:
5.1 No matter – alarms, accepted in any time after being registered or unaccepted at all.
5.2 More – alarms will be returned, accepted with a delay, exceeding the entered threshold value.
5.3 Less – alarms will be returned, accepted with a delay, not exceeding the entered threshold value.
5.4 Interval – alarms will be returned, accepted with a delay, belonging to the entered threshold value.Info title Note. This setting is enabled if the values No matter or Processed are selected from the Alarm processed list.
- From the list Alarm processed (7) select the required filter according to the alarm processing factor:
- No matter — both processed and unprocessed events will be returned.
- Alarm is not processed — only unprocessed events will be returned.
- Alarm processed — only processed events will be returned.
- In the Alarm accepted by group (8), set the checkboxes for the operators who received the alarm events to display these events in the search query.
In the Alarm type group (9), set the checkboxes for the alarms, which have to be returned in results of search query:
Stop over stop line — events will be returned for which stopping over the stop line at the stoplight has been registered.
Entered the oncoming lane — events will be returned for which entering the oncoming lane has been registered.
Parking violation — events will be returned for which the violation of parking rules has been registered.
Marking rules violation — events will be returned for which the violation of marking rules has been registered.
LP found in database — events will be returned which plates have been found in the external database.
Stop over crosswalk line - events will be returned for which stopping over the crosswalk line at the stoplight has been registered.
Overspeeding — events will be returned for which overspeeding has been registered.
Running a red light — events will be returned for which running a red light has been registered.
Running a red light at crossroads — events will be returned for which running a red light at crossroads has been registered.
Alarm is set by operator — manually triggered alarms will be returned.
- From the Search operation list (10), select the logical construct which is used to combine several elements of the key phrase, that correspond to the comments to the events to be searched in external databases:
- AND - to search for comments that contain all the elements of the key phrase;
- OR - to search for comments that contain at least one element of the key phrase.
- In the Comment from external BDDB field (11), enter a key phrase consisting of one or more elements, separated by commas, that correspond to the comments to the events to be searched in external databases that are specified in the External DB group (2) (see Creating the Active tracking database).
From the Speeding list (12) select the required speeding filter and then in the activated field(s) (13) enter the threshold value(s) of speeding in km/h.
Info title Note. This setting is enabled if the checkbox Speeding is set in the Alarm typegroup (9).
Info title Note. The value of speeding is calculated as a difference between the fixed vehicle speed and the speed, permitted on the controlled area of the road.
The following filters of the speeding are available:
6.1 No matter – events of the vehicle, moving with any overspeeding or with the absence of it will be returned.
6.2 More – events of the vehicle, moving with overspeeding, exceeding the entered threshold value will be returned.
6.3 Less – events of the vehicle, moving with overspeeding, less than the entered threshold value will be returned.
6.4 Interval – events of the vehicle, moving with overspeeding, in the entered range of threshold values, will be returned.From the Red light shows at, sec list (14) select the required filter for red light start and then in the activated field(s) (15) enter the threshold value(s) in seconds.
Info title Note This setting is enabled if the checkbox Red light violation is set in the Alarm typegroup (9).
The following filters of the running a red light are available:
6.1 No matter – events of the vehicle, which violated a red light, will be returned.
6.2 More – events of the vehicle, which violated a red light after the entered threshold value will be returned.
6.3 Less – events of the vehicle, which violated a red light before the entered threshold value will be returned.
6.4 Interval – events of the vehicle, which violated a red light within the entered range of threshold values, will be returned.In the Alarm initiated by field (16) select the required operators who initiated the alarm. The corresponding alarms will be shown in the search results.
Info title Note This setting is enabled if the checkbox Alarm is set by operator is set in the Alarm typegroup (9).
...