Go to documentation repository
Page History
...
№ | Parameter | Method for entering the parameter | Parameter description | Symbols used | Default value | Value range |
The Settings group | ||||||
1 | Event viewer clearing time | Enter a value in the field using the up and down buttons | Indicates the time of day at which to start cleaning up the Event Viewer database in accordance with the Events archive length parameter. | HH:MM:SS | Current system time at the moment of object setting panel opening | 00:00:00 to 23:59:59 |
2 | Events archive length | Type-in the value in the field | Sets the number of days for keeping the information about the events registered by the Intellect™ system and recorded in the Event log. This parameter influences on all computers in the distributed system. | Days | 3 | Not less than 0 |
23 | Object code | Type-in the value in the field | Defines the number of the access control card, which is automatically displayed in the User settings panel, when the object is being created in the Facility code field. | Sequence of numbers | Not defined | More than 1 |
34 | Run macro at start | Is selected from the list | Defines the macro command, which will be automatically launched with the Intellect™ system startup. | Names of the Macro command objects registered in the system | Not defined | Depends on the number of Macro command objects created in the digital distributed video surveillance system. |
45 | Connections in the architecture | Is identified by the check mark | Specifies computers with which the created Computer object is to exchange system configuration parameters data: with all computers in the video surveillance system with distributed architecture or only with the Computer object under which the object was created. | Boolean type | Not available | Yes – when creating a new computer the Connection checkboxes in the Architecture tab are set checked for all computers in the architecture. No – when creating a new computer the Connection checkbox in the Architecture tab is set checked only for the computer on which this new object is created. |
56 | DNS instead of IP allowed | Checkbox | Enables setting address of Server/Remote Administrator’s workplace/Remote Client in the Architecture tab as DNS name - not only IP address. | Boolean type | No | Yes – DNS name (instead of IP address) of Server/Remote Administrator’s workplace/Remote Client can be specified in the Architecture tab when configuring computer interoperability in distributed system. Validation of the specified address is disabled. No – IP address of Server/Remote Administrator’s workplace/Remote Client is to be specified in the Architecture tab when configuring computer interoperability in distributed system. |
67 | Ping (sec.) | Type-in the value in the field | Sets Server-computer ping period. | Non-negative integer number | 10 | >=0 |
78 | Show documentation by clicking F1 | Set the checkbox | Enables opening documentation in the pdf format by clicking F1, when Intellect is started. Administrator's Guide is opened on the Server and Remote Administrator’s workplace; Operator's Guide is opened on the Remote Client. | Boolean type | No | Yes – documentation is shown by clicking F1. No – feature of showing documentation by clicking F1 is disabled. |
89 | Administrator’s password | Click the button | Gives a command to open a dialog box for assigning the Administrator’s password. | - | - | - |
The Internal synchronization group | ||||||
910 | offline | Checkbox | Enables offline synchronization of events | Boolean type | Yes | Yes – offline synchronization is enabled. When the computer is reconnected, it gets all the events for the period there was no connection. No – offline synchronization is disabled. When the computer is reconnected, it does not get the events for the period there was no connection. |
1011 | online | Checkbox | Enables online synchronization of events | Boolean type | Yes | Yes – online synchronization is enabled. Events are sent right after they happen according to computer interaction configuration parameters. No – online synchronization is disabled. Events are not sent. |
Holidays group | ||||||
1112 | Date* | - | List of calendar days which will be defined as holidays in the Intellect software | Date | Not specified | Date format:: DD-MM-YY |
1213 | Add | Click the button | Opens the Calendar dialog box to set the date of new holiday | - | - | - |
1314 | Delete | Click the button | Deletes the selected holiday date from the Date list | - | - | - |
1415 | Change | Click the button | Opens the Calendar dialog box to change the selected holiday date in the list | - | - | - |
The RabbitMQ tab | ||||||
1516 | Server | Type-in the value in the field | Sets the RabbitMQ host address | Latin characters, digits and service characters | localhost | Host IP address or name |
1617 | Port | Type-in the value in the field | Sets the RabbitMQ host port | Latin characters, digits and service characters | 5672 | 0 – 65535 |
1718 | User | Type-in the value in the field | Sets the RabbitMQ host user name | Latin characters, digits and service characters | guest | Depends on registered RabbitMQ users |
1819 | Password | Type-in the value in the field | Sets the RabbitMQ host user password | Latin characters, digits and service characters | guest | Depends on registered RabbitMQ users |
1920 | Content-type | Select from the list | Sets the type of content sent/received | Supported content type | plain/text | application/json – a message in JSON format is sent/received plain/text – Intellect event is sent/received in the following format: "TYPE|ID|EVENT" |
...