Core

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (x32)
x64: (x64)

ChangePort

> = 0

Depends on the port specified for the Client.

4.7.3 and later

Allows changing the port number. For instance, if it is necessary to change port 20900 to 40900, then 20900="40900" string parameter is created.
The change of this parameter can affect the system.

x32: (x32)
x64: (x64)

CheckPingPeriod

> 0

 10

4.7.4 to 4.10.2

Sets Server-computer ping period.

Note. In Intellect since version 4.10.3 this parameter is set on the settings panel of the Security zone object.

x32: (x32)
x64: (x64)

CheckVersion

0, 1

0

4.7.4 and later

Sets the parameters of Server connection: the version is checked in connected version parameters. If versions do not agree, then there is a corresponding message and no connection.

x32: (x32)
x64: (x64)

Core IP Address

IP address

 -

4.7.3 and later 

Address of the computer to the core of which the slave.exe is to connect.

x32: (x32)
x64: (x64)

DBAttempts

1..∞

 10

4.7.3 and later

Number of attempts to connect to database.

x32: (x32)\Debug
x64: (x64)\Debug

DebugLevel

0,1,2,3,4

0

4.7.3 and later

Sets the debug mode:
0 – disabled;

1 – information is shown in the process window;

2 – information is shown in the process window and logged;

3 – extended log is written – it contains module events;

4 – extended log is written – it contains module events and parameters.

x32: (x32)\Debug
x64: (x64)\Debug

DebugExtension

Any string

LOG

4.7.3 and later

Sets extensions of log files.

x32: (x32)\Debug
x64: (x64)\Debug

DebugFlushPeriod

> = 0

500

4.7.4 and later

Sets the update rate for log files (ms).

x32: (x32)\Debug
x64: (x64)\Debug

DebugOptions

Range in decimalsystem: 0-255. 

0x001 (i.e. 1)

4.7.3 and later

Hexadecimal logging in the debug mode. This parameter has a complex structure (bit mask) and it is modified using the Tweaki.exe utility.

x32: (x32)\Debug
x64: (x64)\Debug

DebugQueueMaxLines

0 - 2147483647

2000

4.7.4 and later

Specifies max. number of messages in a queue to log file. If there are more than 500 log lines in the queue, then they are to be scaled.

x32: (x32)\Debug
x64: (x64)\Debug

DebugSize

>=100

100

4.7.3 and later

Specifies the number of megabytes provided for log. Restricted by disk capacity.

x32: (x32)\Debug
x64: (x64)\Debug

DebugTime

 0-2147483647

48

4.7.3 and later

Specifies the number of hours for keeping log files.

x32: (x32)\Debug
x64: (x64)\Debug
DebugZipDays>024.7.5 and laterSpecifies the number of days for keeping log files in the gz format.

x32: (x32)
x64: (x64)

defaultconnection

 0, 1

1

4.7.4 and later

Allows setting connections in the architecture only with the computer where the Computer object is created.

x32: (x32)
x64: (x64)

DisableProtocol

0, 1

0

4.7.3 and later

Allows disabling protocol.

x32: (x32)
x64: (x64)

DisableThreadStatQueue

0, 1

0

4.8.0 and later

 

By default the key is not created.

 

Defines whether the queue statistics is called or not. If the registry key value=1, then the box can not be called.

 

To call the Queue statistics box, follow the steps:

 

  • Intellect 4.9.2 and older – press F2
  • Intellect 4.9.3 and later – press Alt+F2 key combination


x32: (x32)
x64: (x64)

InstallFolder


Intellect

4.7.3 and later

Specifies the installation folder.

x32: (x32)
x64: (x64)

Ip_port

0, 1


up to  4.7.6

Specifies the port using which the IP camera will operate on the Computer object.

x32: (x32)
x64: (x64)

Language

0x0419

-

4.7.3 and later

Specifies the language to use (0x0419 - English). 

x32: (x32)
x64: (x64)

LogIncommingMsg

0, 1

not created

up to  4.8.0

Defines whether logging of incoming events is enabled or not.

x32: (x32)
x64: (x64)

LogOutgoingMsg

0, 1

not created

up to  4.8.0

Defines whether logging of outgoing events is enabled or not.

x32: (x32)
x64: (x64)

LogStatistics

0, 1

not created

up to  4.8.0

Defines whether the statistics is logged or not.

x32: (x32)
x64: (x64)

OnlyLocalProtocol

0, 1

0

4.7.3 and later

Only local events are logged.

x32: (x32)
x64: (x64)

PeakWorkingSetSizeQuota

>=0

0

4.8.1 and later

Sets RAM limit (MB). When this limit is exceeded, the module that exceeded this limit will be restarted in the restart service.

x32: (x32)
x64: (x64)

PhotoCores

Name or IP address 

-

4.7.3 and later

The list of computers (cores) for mailing user photos.

x32: (x32)
x64: (x64)

PriorityClass

256,

128,

32768,

32,

16384,

64

 16384

4.7.3 and later

Defines the stream priority:

256 - realtime

128 - high

32768 - Above Normal

32 - normal

16384 - below Normal

64 - low

x32: (x32)
x64: (x64)

ShowCrashMessage

0, 1

0

4.7.5 and later

Create or not the module crash message. 

x32: (x32)
x64: (x64)

SyncTime

0, 1

0

4.7.3 and later

Defines whether to synchronize time between computers or not.

x32: (x32)
x64: (x64)

Topmost

0, 1

1

4.7.4 and later

Sets the splash screen location:
1 - splash screen is topmost;
0 - screen is hidden behind other windows.

This key is applied for splash screen on the Server/Remote Administrator’s workplace for Intellect versions older than 4.10.0, for versions newer 4.10.1 - both on the Server/Remote Administrator’s workplace and on the Client.

x32: (x32)
x64: (x64)

Type_view_dept_log

0,1,2

0

4.7.4 and later

Specifies displaying the  name of department in the log:

0 - do not add:  Ivanov Ivan Ivanovich;  
1 - add to the beginning:
[Sales department] Ivanov Ivan Ivanovich;
2 - add to the end:
Ivanov Ivan Ivanovich [Sales department].

x32: (x32)
x64: (x64)

URAttempts

 0 - 10000

3

4.7.3 and later

Sets the number of attempts to enter the user password .

x32: (x32)
x64: (x64)

URDelay

 0 - 10000

60

4.7.3 and later

Sets the delay period (sec) for re-entering the system.

x32: (x32)
x64: (x64)

virtualgrabber

0, 1

0

4.7.6 and later

Defines whether it is possible to create  a virtual video capture card or no.

x32: (x32)
x64: (x64)

SyncNotEmpty

0, 1

0

4.8.5 and later

Defines the database synchronization algorithm:

1 – fast synchronization algorithm is in use;

0 -  standard synchronization algorithm is in use.

x32: (x32)\Debug
x64: (x64)\Debug

counter_period

>=0

0

4.9.0 and later

Defines the time period in seconds, in which information about availability of processor, memory and disk is recorded to the log-file. If the value of parameter is 0, this information is not included to the log-file.

x32: (x32)\ IntellectRunService
x64: (x64)\ IntellectRunService

RestartIntellectOnLogonDisable

0, 1

0

4.9.0 and later

1 – Intellect installed as a Service is not restarted under the current user even for users belonging to the IntellectUsers group.

0 – Intellect installed as a Service is restarted under the current user only if the user belongs to the IntellectUsers group.

x32: (x32)\ IntellectRunService
x64: (x64)\ IntellectRunService

CheckUserForRestartIntellectDisable

0, 1

-

4.9.0 and later

0 – Intellect installed as a Service is restarted (when entering the system) under the current user only if the user belongs to the IntellectUsers group.

1 – Intellect installed as a Service is restarted (when entering the system) under the current user even if the user doesn’t belong to the IntellectUsers group. The settings of permissions are to be taken into account when using this key. If the permissions are set incorrectly, then some Intellect features can operate incorrectly.

x32: (x32)
x64: (x64)

ShowHiddenObjects

0, 1

0

4.9.0 and later

0 – hidden objects corresponding to IntegratedAudioSource and IntegratedVideoSource objects, as well as to Integrated device child objects are not shown in the object tree in Intellect.

1 – hidden objects are shown in the object tree in Intellect.

Intellect is to be restarted when the key value is changed.

x32: (x32)
x64: (x64)

InheritServiceEnviroment

0, 1

-

4.8.8 only

The key is essential for proper operation of Intellect in MS failover cluster.

x32: (x32)\ IntellectRunService\
x64: (x64)\ IntellectRunService\

InheritServiceEnvironment

0, 1

-

4.9.0 and later

The key is essential for proper operation of Intellect in MS failover cluster.

x32: (x32)
x64: (x64)

SortCamsById

0, 1

-

4.8.8 and later

The key is responsible for sorting the list of cameras on the settings panelof the Monitor object.

1 – cameras are sorted by ID;

0 – cameras are sorted by names.

x32: (x32)
x64: (x64)

EventProcessingThreads

>=0

0

4.9.0

Key reserves the specified number of streams for events processing.

0-8Equal to CPU cores number4.10.4

x32: (x32)\Debug
x64: (x64)\Debug

DumpYUV

0, 1

-

4.9.0.959

Key activates the mode of video dump corresponding to compressor.  It is required for diagnostics of StreamLabs (motionWavelet7.1) compressor/decompressor problems.

File (or files) with decompressed data will be created by key in the Modules directory. Names of files correspond to the template:
WxH_hv_chunk_№.yuv

W – width;
H – height;
h – horizontal subsampling;
v – vertical subsampling;
№ - number of file. If resolution or subsampling are changed the new file openes.

For example, file with resolution 640x480 in YUV420 color area will have the 640x480_22_chunk_0.yuv name.

x32: (x32)
x64: (x64)

settings_height>0, depends on screen resolution438
Sets the height of the object settings panel (in pixels).

x32: (x32)
x64: (x64)

settings_width>0, depends on screen resolution600
Sets the width of the object settings panel (in pixels).
x32: (x32)
x64: (x64)
ATMSendSetup0, 114.9.3

0 – receiving of the SETUP reaction from the ATM object is disabled on the computer where this key is specified.

1 - receiving of the SETUP reaction from the ATM object is enabled on the computer where this key is specified. 

x32: (x32)
x64: (x64)
RegisterF10andF110, 114.9.2

1 - F10 and F11 hot keys are in use to control screen displaying (see Main control panel section).

0 - F10 and F11 hot keys are not in use to control screen displaying.

Note.When the key is changed Intellect restart is required. 

 To disable F10 and F11 hot keys on the Administrator Remote Workplace, the key is to be created in the  \HKEY_CURRENT_USER\Software\ITV\Intellect registry section.

To disable F10 and F11 hot keys on the Administrator Remote Workplace when operating under the Admin account, he key is to be created in the same registry section as on Server (x32)/(x64).

x32: (x32)
x64: (x64)
DisableF80, 104.10.4

0 -  F8 hot key is in use to call the Execute menu on the main control panel.  

1 - F8 hot key is not in use.

Note. To disable F8 hot key on the Administrator Remote Workplace, the key is to be created in the  \HKEY_CURRENT_USER\Software\ITV\Intellect registry section.

To disable F8 hot key on the Administrator Remote Workplace when operating under the Admin account, he key is to be created in the same registry section as on Server (x32)/(x64).

x32: (x32)
x64: (x64)

check_digital0, 104.8.0

When the key value = 1, video or archive period is exported from the Monitor interface using the admin password.

x32: (x32)
x64: (x64)
CONNECT_ATTEMPTS>=114.9.4The key sets the number of attempts to connect the Client to Server. The key is specified on the side of the Client.
x32: (x32)
x64: (x64)
FLUSH_TIMER_TIMEOUT>0

By default the key is not created, the value is 10.

4.9.4

The key specifies maximum waiting time (in milliseconds) before sending data over the network.

The higher the value of this parameter, the more productive the system is (due to decreasing resources when sending a large amount of small messages).

However, time of response to events can also increase.
x32: (x32)
x64: (x64)
UnloadDelay0 to 60000 ms50004.9.5

The key sets the delay between disabling Guardant and unloading Intellect.

The delay is essential for the FORCED_OFF event generation of the SLAVE object and in case this event is used in scripts or programs, these scripts and programs are executed.

If UnloadDelay = 0, unloading is performed without any delays, i.e. script/program in which the specified event is used, cannot execute.
x32: (x32)
x64: (x64)
SortSubItems0, 11-

The key is for specifying the way of sorting the objects in the tree:

0 – sorting by name.

1 – sorting by ID.

Note 1. If sorting by name is chosen, and there are numbers in the object name, then the objects will be sorted in alphabetical order. For example, an object with the name "115" will be above the object with the name "15", because in the name "115" the second number is 1, and in the name "15" the second number is 5.

Note 2. This key also affects the sorting of objects in the tree when adding the objects to a layer in the Map Editor utility.

x32: (x32)
x64: (x64)
ShowSmallBarAlways0, 104.10.1

The key enables displaying the main control panel of Intellect on the screen.

0 – the main control panel is displayed when pointing to the upper right corner of the screen.

1 – the main control panel is always displayed in the upper right corner of the screen.
x32: (x32)
x64: (x64)
UpdateProtocolPeriod> 0-4.10.2

Sets time period (in days) of storing the change protocol in the database.

The storing period is counted from the last recording or starting from the current time depending on the value of the ClearProtocolFromCurrentTime key (see above).

Recordings storing period of which has expired are deleted at midnight every 24 hours in case the license is activated.
x32: (x32)
x64: (x64)
permissible_memory_limit>0-4.10.3The key sets the occupied memory threshold, reaching which the core starts receiving messages with a delay. The key should be used when due to excessive memory consumption, the module shuts down.
x32: (x32)
x64: (x64)
MsgCompressOn0, 104.10.3

The key enables the compression of transmitted messages:

0 - compression is disabled.

1 – messages from the cores are sent compressed (zip with maximum compression). Compression allows reducing the network load.

x32: (x32)
x64: (x64)
user_card_info_on0, 10Intermediate versions 4.10.3

The key is used with the ACS/FAS integration modules that are the part of ACFA Intellect. It enables displaying the access card number for all events associated with the cards in the Event Viewer.
0 - the access card number is not displayed in the Event Viewer.
1 - when an event comes from the ACS device, the param1 parameter is interpreted as an access card number and is displayed in the Event Viewer in the Card column. This column is automatically added to the Event Viewer window when the first such event is received.

Note. In the released version 4.10.3 to show and hide the Card column use the Hide Card checkbox – see Event viewer parameters.

x32: (x32)
x64: (x64)
CriticalErrGui0, 104.10.3It enables displaying messages about database connection errors regardless the debugging mode (see the description of the Debug key and Selecting and enabling the debug mode of Intellect software section).
0 - messages about database connection errors are displayed only at Debug 4 debugging levels.
1 - messages about database connection errors are displayed regardless the selected debugging level.
x32: (x32) 
x64: (x64)
IntellectCloseTimeout>0600004.8.3It sets Intellect close timeout in milliseconds. If intellect.exe process does not close during this timeout, then it is terminated forcefully. If there is no key, then timeout is 60 seconds.
x32: (x32)
x64: (x64)
SaveIncommingMsg0, 104.7.8

It enables recording of incoming messages to log files for started modules. The file name looks like <module name>.exe.cd.log.

These files are stored in the same folder as the executed module file, for instance, for intellect.exe the intellect.exe.cd.log file is stored in the Intellect installation directory and for itvscript.exe the itvscript.exe.cd.log file is stored in the Modules folder.

When the size of the log file exceeds 4 GB, it is archived to the backup file with .bak extension - <module name>.exe.cd.log.bak. This is necessary to avoid module overload.

Note. The log file is rewritten when Intellect is restarted.

0 – recording of incoming messages is disabled.

1 – recording of incoming messages is enabled.

x32: (x32)
x64: (x64)
BackupFolderAddress of a local or network folder-4.7.6Specifies the address of the folder to save a backup copy of the database created by a macro or using the idb.exe utility.
For example, C:\Documents and Settings\AVP\Desktop\Backup

If the database copy is to be stored on the network disk, then the UNC path to the network folder (with the recording access) is to be specified on the disk in the \\ServerName\ShareName format. Take into account the fact that all network resources that require additional authentication are to be enabled using the same username as for running the SQL Server service.

See also Creating the database backup copy

х32 and x64:

HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon

ShellAny text valueexplorer.exe4.10.5If the key value contains the "explorer" string (for example, the default value, "testexplorertest" or "123explorertest125" values), the Save button is displayed in the About program... window. Otherwise, the Save button is hidden.
x32: (x32)\ IntellectRunService
x64: (x64)\ IntellectRunService
IntellectUserGroupAny text value
from 4.10.0If Intellect is installed as a Service, and you need to use a user group other than IntellectUsers, then specify the required user group name in this key.
x32: (x32)
x64: (x64)
monitor_refresh_delay10 - 30003000from 4.10.5

The key sets a period in milliseconds to update video on Video Surveillance Monitors of the Clients after Failover Service has transferred configuration.

If the key value is less than 500, the monitors are updated regardless of the number of cameras.

If the key value is more than 500 and the number of cameras on the monitor is more than 64, the update does not occur while the System Settings dialog box is open.

x32: (x32)
x64: (x64)
DisableUpdateProtocol0, 10from 4.7.5The key disables the filling of the UPDATE_PROTOCOL table storing information about changes of Intellect object settings (except the User objects).
0 – the UPDATE_PROTOCOL table is filled.
1 – the UPDATE_PROTOCOL table is not filled.
x32: (x32)
x64: (x64)

max_disp_menu_items

>050from 4.10.5If the number of screens assigned to a computer is larger than that specified in the key, scrolling the list of screens with the mouse wheel becomes available (if the size of the list is larger than the size of a computer monitor).

The key is set on each Server and Client where this function is required.
x32: (x32)
x64: (x64)
URM_ProcessWait>010000from 4.10.5

The key sets time period in milliseconds to wait for the Client to stop before aborting the Video.run process.

The key should be created on Clients.

x32: (x32)
x64: (x64)
show_responsible0, 10from 4.10.5

The key enables the display of users responsible for the region (if assigned) in events from objects related to the regions:

  • In the Event Log – in the Add.info field.
  • In the Operator protocol – in the event box next to the name of the region.
  • On the Map - in the Output window on the Object Info tab

The key is created on the Server.

x32: (x32)
x64: (x64)
NotifyExpireLic0, 10from 4.10.5The key enables the event showing the days left to the license expiration (see SLAVE).
x32: (x32)
x64: (x64)
sync_timeout>0600from 4.10.5The key sets the time period in seconds allocated for synchronizing the database when starting Intellect software. The key must be created on the Server, where synchronization with another server occurs. See also Database synchronization setup
x32: (x32)\Display
x64: (x64)\Display
DISPLAY_MAX_NUM1-1000500from 4.10.5The key sets the maximum number of Display objects that can be assigned to one computer.
х32: (x32)\
x64: (x64)\
RestPort0 - 65535101120from 4.10.1 to 4.10.2Sets the port through which Intellect receives events and reactions via HTTP request. See also Sending reactions and events to Intellect using HTTP request.
0from 4.10.3
x32: (x32)\
x64: (x64)\
ADSyncOnStart 0, 10from 4.10.5

The key enables synchronization with Active Directory when starting Intellect software.

0 - synchronization with AD when starting Intellect is disabled.

1 - synchronization with AD when starting Intellect software is enabled.

TABLE OF CONTENTS


Telemetry

Registry section

String parameter

Available values

Default

Product version

Parameter in effect

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

Delay

> = 0

250

4.7.3 and later

Defines the delay (ms) when sending commands to the camera. This key is essential for scaling the stream of commands to the device as some devices can be blocked because of too many commands and cannot process the information.

 

This parameter is not supported by IP cameras.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

JoysticThreshold

> = 0

5

4.7.6 HOTFIX and later

This parameter sets the joystick trigger threshold: the less the number is, the more sensitive joystick is.

0 value is not recommended to be used, as commands can be sent randomly.  When the value is too big, the joystick becomes rotation-insensitive.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

max_speed

0-10

-

4.7.3 to 4.9.7

Sets max. camera speed.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

min_speed

0-10

-

4.7.3 to 4.9.7

Sets min. camera speed.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

PriorityDelay

> =  0

30000

4.7.3 and later

Defines the priority delay (ms).

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

UseBoschOSRD40

0, 1

-

4.8.4 and later

Enables presets saving for Bosch-Autodome control protocol.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

PnPJoystick

0, 1

0

4.8.3 and later 

The key defines whether to restart Intellect after connecting a joystick:

0 - Intellect is to be restarted after connecting the joystick.
1 - Intellect is not to be restarted after connecting the joystick.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY

Zenable

0, 1

1

4.7.7 and later 

The key is in use with joysticks (e.g., Logitech Attack 3) where the telemetry control operates incorrectly because of shifted Z axis. Z axis is disabled when the parameter value is 0.  Z axis is enabled when the parameter value is 1.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
ZoomSpeed8500,114.9.0 and later 

The key is used in order to set the zoom step when panasonic-850 telemetry protocol is in use:

1 – zooming with 50% step of max. possible

0 – zooming with 20% step of max. possible

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
Zdirection0, 104.7.6

The key is responsible for coordinate move in the Z-direction.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
Ydirection0, 104.7.6

The key is responsible for coordinate move in the Y-direction.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
Xdirection0, 104.7.6

The key is responsible for coordinate move in the X-direction.

x32: (X32)\
TELEMETRY
x64: (x64)\TELEMETRY
WaitDelay>=004.7.5If a joystick sends the messages about its state to Intellect too frequently and Intellect has no time to process these messages, then this parameter is in use – it allows calling the signal handler less frequently. For instance, this parameter should be used with Axis 295 joystick. The best parameter value is to be chosen. The value should match the 100 – 300 range.      
x32: (x32)\
TELEMETRY
x64: (x64)\TELEMETRY
TelemetryDirectCommand0, 114.9.8

The key specifies way of  command transmission to telemetry:

1 – telemetry server is connected to video servers and sends commands to devices.

0 – telemetry server sends commands to the Intellect core which send them to devices.

See also description of the MonitorToTelemetryDirectCommand key below.

x32: (x32)\
TELEMETRY
x64: (x64)\TELEMETRY
MonitorToTelemetryDirectCommand0, 104.9.8

The key specifies way of transmission telemetry commands while control from the Monitor:

1 – telemetry server is connected to video servers and sends commands to devices while telemetry control from the Monitor.

0 – telemetry server sends commands to the Intellect core which send them to devices while telemetry control from the Monitor.

The key is in use with the TelemetryDirectCommand key to provide smoother telemetry control. Recommended values of these keys:

TelemetryDirectCommand = 1 (default value)

MonitorToTelemetryDirectCommand = 1 (attention: default value is 0)

Attention! Client, server and camera should be in one subnet without video gate when using these registry keys. Otherwise, systemwillnotoperate.
x32: (x32)\
TELEMETRY
x64: (x64)\TELEMETRY
SendEventToCore0, 104.10.0

The key is to enable the function of sending events to Intellect core when controlling PTZ. This function is essential for PTZ control audit.

1 – when sending any reaction of TELEMETRY object the corresponding event is generated.

0 – during PTZ control events are not generated.
x32: (X32)\
Video\CommonPresets
x64: (x64)\Video\CommonPresets
ONVIF0, 104.10.0

The key enables presets created on the camera in Intellect. The function is only available when camera is connected via ONVIF protocol and only if video server settings are selected when adding a Video capture device using the Camera discovery tool and the Use device settings checkbox is set unchecked on the settings panel of the Video Capture Device object.

0 – presets created on the camera are not used in Intellect.

1 – presets created on the camera are in use in Intellect. The features are listed below:

  1. The preset ID on the camera is to be the same as the preset ID in Intellect or differ by 1 depending on the camera features (see item 2).
  2. As preset numeration starts differently on various cameras (with 0 or 1), then preset numbers can differ by 1 in Intellect. If the numeration on the camera starts with 0, then numeration in Intellect is the same. If the numeration on the camera starts with 1, then numeration in Intellect is greater by 1 (for instance, the first preset on the camera corresponds to the second in Intellect and the first in Intellect is not active).
x32: (x32)\
TELEMETRY
x64: (x64)\TELEMETRY
panas850_stop_dublicates>0-4.10.2The key is in use if the camera rotation is not stopped when telemetry is controlled over Panasonic-850 protocol. The key specifies how many times the stop command is to be duplicated. 

...