Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Forwarding the configuration to This section describes how to manage the configurations of all ZK Teco controllers is described in this section. Also it's possible to forward the configuration to each controller separately connected to the ACFA-Intellect Server at once. It is also possible to manage the configuration of each ZK Teco controller separately (see the Managing the configuration of a ZK controller section).

To forward manage the configurations of all ZK Teco ACS's configuration controllers at once, do the following:

  1. Go to the settings panel of the AC ZK Teco object.
  2. Click the Set current time to all devices button (1) to synchronize the time of all the devices controllers with the Intellect Server time.
  3. To send Click the Send access settings to all devices click the corresponding button devices button (2) to start sending the access settings to all controllers.To cancel
  4. Click the Cancel sending the access settings to  to all devices, click the corresponding button button (3) to cancel sending the access settings to all controllers.To display the progress of
  5. Click the Suspend sending access settings to all devices button (4) to suspend sending the access settings to all devices in the event log, click the corresponding button (4)controllers.
  6. Click the Progress sending access settings to all devices button (5) to resume sending the access settings to all controllers if it was previously suspended.
  7. Set the Dynamic access settings checkbox for automatic forwarding to automatically send the data of the Access Manager module to devices  module to all controllers (6).
  8. Click the Apply button (7).

Managing the configurations of all ZK Teco controllers is now complete.