- Go to the settings panel of the corresponding ZK Teco controller.
- From the Gate drop-down list (1), select the type of controller connection (see Configuring the connection via Ethernet standard or Configuring the connection via RS-485 standard).
- In the Password field (2), enter the password for controller connection.
- If the Ethernet connection type was selected, then enter the IP address of the controller in the IP field (3).
- If the the RS-485 standard connection type was selected, then select the connection COM port number from the Address drop-down list (3).
From the Anti-passback drop-down list (4), select the mode of anti-passback operation:
Mode
Description
Controller
Disable
The anti-passback function is disabled All controllers Readers of Door 1 The anti-passback function is enabled between the readers of Door 1 ZK C3-100, ZK C3-200 Readers of Door 2 The anti-passback function is enabled between the readers of Door 2 ZK C3-200 Readers of door 1, readers of door 2 The anti-passback function is enabled between the readers of Door 1 and Door 2 respectively ZK C3-200 Door 1 and 2 The anti-passback function is enabled between the readers of Door 1 and Door 2 ZK C3-200, ZK C3-400 Doors 3 and 4 The anti-passback function is enabled between the readers of Door 3 and Door 4 ZK C3-400 Doors 1 and 2, doors 3 and 4 The anti-passback function is enabled between the readers of Door 1, Door 2, Door 3 and Door 4 ZK C3-400 Doors 1, 2 and doors 3, 4
The anti-passback is enabled between Door 1, 2 and Door 3, 4 ZK C3-400 Door 1 and doors 2, 3 The anti-passback is enabled between Door 1 and Door 2, 3 ZK C3-400 Door 1 and doors 2, 3, 4 The anti-passback is enabled between Door 1 and Door 2, 3, 4 ZK C3-400 From the Interlock drop-down list (5), select the mode of doors interlocking:
Mode
Description
Controller
Disable
The interlock function is disabled All controllers Door 1 and 2 Doors 1 and 2 are interlocked mutually ZK C3-200, ZK C3-400 Door 3 and 4 Door 3 and door 4 are interlocked mutually ZK C3-400 Doors 1, 2 and 4 Door 1, door 2 and door 4 are interlocked mutually ZK C3-400 Doors 1 and 2, doors 3 and 4
Door 1 and door 2 are interlocked mutually, door 3 and door 4 are interlocked mutually ZK C3-400 Doors 1, 2, 3 and 4 Door 1, door 2, door 3 and door 4 are interlocked mutually ZK C3-400 Info title Note To open one of the interconnected doors, the other interconnected doors in the group must remain closed. This means that in a group of interconnected doors, only one door can be opened at a time.
- From the Backup period drop-down list (6), select the time interval in minutes for the automatic backup of data of the specified type (see Managing the configuration of a ZK controller).
Set the Watch dog checkbox (7) to enable the automatic data backup.
Click the Apply button (9).
Info title Note. If After a successful connection with the controller is established, the firmware version and the controller serial number will automatically be displayed in area (8).
...