The Vehicle Tracker Tracer settings panel contains the following interface elements:

...

The following table describes the elements of the Vehicle Tracker Tracer object settings panel.

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

ID number

Automatically

Displays the Vehicle

Tracker 

Tracer object's ID number in the system

Number

-

From 1 and above.
Depends on the number of Vehicle

Tracker

Tracer objects in the system

2

Name

Enter the value in the field

Set the Vehicle

Tracker 

Tracer object name in the system

Latin, Cyrillic and special symbols

The Vehicle

Tracker

Tracer

A sting, containing a sequence of characters (letters, digits, characters)non case-sensitive
Number of characters if from 1 to 60

3

Disable

Is set with a checkbox

Set the Vehicle

Tracker 

Tracer object's state (enabled or disabled) in the system

Boolean type

No

Yes –The Vehicle

Tracker

Tracer object is disabled and not in use
No – The Vehicle

Tracker

Tracer object is enabled and in use

4

Screen

Select from the list

Set the screen parent object in the system, to which this Vehicle

Tracker 

Tracer object is related

Names of Screen objects, registered in the system

Name of the Screen parent object

Depends on the number of Screen objects

5

Basic

Go to the tab

Access to settings of the component position Active monitor on the screen

-

-

-

6

Show

Is set with a checkbox

Displays the Active monitor component on the screen

Boolean type

No

Yes – Active monitor components is displayed on the screen
No – Active monitor components is not displayed on the screen

Coordinates group on the Basic tab

 


7

 

 

 

 

 











Field X

Enter the value in the field

Set the horizontal coordinate of the X axis of the Active monitor's component left upper corner on the screen

% regarding the screen's width

-

From 0 to М*100, where М – is the number of installed video surveillance monitors

Field Y

Enter the value in the field

Set the vertical coordinate of the Y axis of the Active monitor's component left upper corner on the screen

% regarding the screen's height

 


From 0 to М*100, where М – is the number of installed video surveillance monitors

Field W

Enter the value in the field

Set the width of the Active monitor's component

% regarding the screen's width

-

From 70 to М*100, where М – is the number of installed video surveillance monitors

Field H

Enter the value in the field

Set the height of the Active monitor's component

% regarding the screen's height

-

From 39 to М*100, where М – is the number of installed video surveillance monitors

Button X

Click the button

Entering the text window for visual setting the coordinates and sizes of the Active monitor's component

-

-

-

Allow moving

Is set with a checkbox

Enables moving the Active monitor's component

Boolean type

No

Yes – moving is permitted
No – moving is unavailable

8

Control monitor

Select from the list

Set the Monitor interface object to play back the video archive from the LP recognition camera upon the command from the Vehicle

Tracker

Tracer window

Names of Monitor objects, registered in the system

-

Depends on the number of Monitor objects, registered in the system

9

Settings

Click the button

Access to The Vehicle

Tracker

Tracer interface and also to the voice notification settings while registering the alarms: overspeeding, identification of the plate in the external database

-

-

-

Plates recognizers group

 


10

 

 



Available

Automatically

Displays the list of LP recognisers servers, available for displaying in the Vehicle

Tracker

Tracer interface window

-

-

-

Selected

Automatically

Displays the list of LP recognisers servers,displayed in the Vehicle

Tracker

Tracer interface window

-

-

-

Buttons >, <, >>, <<

Click the button

Selection of LP recognisers servers, to be displayed in the Vehicle

Tracker

Tracer interface window

-

-

-

External databases group

 

 

 

 

 

 

 








11

Available

Automatically

Displays the list of External Plates databases, that may be used for the identified objects analysis

-

-

-

 


Selected

Automatically

Displays the list of External Plates databases, selected for the identified objects analysis

-

-

-

 


Buttons >, <, >>, <<

Click the button

Selection of Platesd databases for the identified objects analysis

-

-

-








12

Monitor

Go to the tab

Access to the settings of Events monitor component on the screen

-

-

-

13

Show

Is set with a checkbox

Displays the Events monitor component on the screen

Boolean type

No

Yes – the Events monitor component is displayed on the screen
No – the Events monitor component is not displayed on the screen

Coordinates group on the Monitor tab

 


14

 

 

 

 

 






15

16

Field X

Enter the value in the field

Set the horizontal coordinate of the X axis of the Events monitor's component left upper corner on the screen

% regarding the screen's width

-

From 0 to М*100, where М – is the number of installed video surveillance monitors

Field Y

Enter the value in the field

Set the vertical coordinate of the Y axis of the Events monitor's component left upper corner on the screen

% regarding the screen's height

-

From 0 to М*100, where М – is the number of installed video surveillance monitors

Field W

Enter the value in the field

Set the width of the Events monitor's component

% regarding the screen's width

-

From 0 to М*100, where М – is the number of installed video surveillance monitors

Field H

Enter the value in the field

Set the height of the Active monitor's component

% regarding the screen's height

-

From 0 to М*100, where М – is the number of installed video surveillance monitors

Button X

Click the button

Entering the text window for visual setting the coordinates and sizes of the Events monitor's component

-

-

-

Allow moving

Is set with a checkbox

Set the possibility of moving the Events monitor's component

Boolean type

No

Yes – moving is permitted
No – moving is unavailable

Alarm window

Go to the tab

Access to the settings of Alarm window component on the screen

-

-

-

Show

Is set with a checkbox

Displays the Alarm window component on the screen

Boolean type

No

Yes – the Alarm window component is displayed on the screen
No – the Alarm window component is not displayed on the screen

Coordinates group on the Alarm window tab

 


17

Field X

Enter the value in the field

Set the horizontal coordinate of the X axis of the Alarm window's component left upper corner on the screen

% regarding the screen's width

-

From 0 to М*100, where М – is the number of installed video surveillance monitors

 

 

 




Field Y

Enter the value in the field

Set the vertical coordinate of the Y axis of the Alarm window's component left upper corner on the screen

% regarding the screen's height

-

From 0 to М*100, where М – is the number of installed video surveillance monitors

Field W

Enter the value in the field

Set the width of the Alarm window's component

% regarding the screen's width

-

From 0 to М*100, where М – is the number of installed video surveillance monitors

Field H

Enter the value in the field

Set the height of the Alarm window's component

% regarding the screen's height

-

From 0 to М*100, where М – is the number of installed video surveillance monitors