Go to documentation repository
Page History
...
The utility allows you to:
Set the external IP address or DNS name of the
switchrouter if the Server is located behind
thethe NAT (1).
Use the following settings format
Address 1Info title Note You may set multiple interfaces using a comma separated list, such as: "IP
Name 1Address1 or DNS
Address 2Name1, IP
Name 2"address2 or DNS
Name2".
For example: 88.78.12.33, ExampleAxxon.ddns.net.
Т
Set the port range for operation of the Axxon Next Server (2-3). To do this, specify the beginning of the range and the number of ports. The number of ports should not be lower than 20.
Note title Attention! Within an Axxon Domain, the port ranges of Servers should not overlap.
Info title Note The number of ports that you select affects the scalability of the system. Keep the following in mind when specifying the number of ports:
- 6 ports is a minimum system requirement for machines with Axxon Next.
- In a 32-bit configuration, for every 32 cameras, 6 ports are required (for multistreaming cameras). In a 64-bit configuration, for any number of cameras, 6 ports are required.
- 2 ports are required to write to the archive.
- To use the Object Tracking database (track recording), 1 port is required.
- To use basic detection tools, 2 ports are required.
- To use Scene Analytics, 2 ports are required.
- To use E-mail- (through SMTP), SMS or server audio notification 1 port is required .
- Restrict the visibility of Servers from various networks in the Servers list during the Axxon Next setup (4). Possible values:
- "0.0.0.0/0" - Servers from all networks will be visible.
- "10.0.1.23/32,192.168.0.7/32" - Only Servers from specified networks will be visible.
- "127.0.0.1" - Only Servers from the local network will be visible.
...