Go to documentation repository
Page History
...
- Go to the configuration panel for the Partition Of Control object.
- Click the Cameras... button. The Add/edit cameras window opens.
- Configure the necessary cameras by clicking the 1). and buttons to move cameras from the left list to the one on the right (
- Select cameras in the list on the right.
- Specify the time for video archive storage, In the Keep archive for (days) field, specify the storage time of the video archive in days (2).
- Click the Set for cameras selected in the right list button (3).
- Repeat steps 4 to 6 for all necessary cameras.
In the Gaps in the archive (days) field, specify the number of days during which the video archive was not recorded, if it is necessary to take into account the standard gaps in the archive (3).
In the Camera connection date field, specify the date the camera was connected to the system (4).
Click the Set for selected cameras listed on the right button (5)
Set the archive tracking time period (4): For all time or Over period (days). When Over period (days) is selected, the (5) field is enabled to specify the number of days.
Info If For all time is selected, the algorithm of decision-making on an alarm for all time is used, even when the video archive is empty.title Note.
If Over period (days) is selected, the value entered in field (5) must be greater than or equal to the archive storage time + 1 day.
To take into account the regular voids in the archive, the number of days in the tracking period should be increased by the maximum number of days of regular voids during the archive storage.
- Click the Apply changes and close button (6). The selected cameras will be added to the list on the configuration panel of the Partition of Control object.
- Click the Apply button on the configuration panel of the Partition of Control object.
Info | ||
---|---|---|
| ||
The ID numbers of cameras and captioners must be whole numbers. |
...
Overview