  1. Go to the Door/reader interface (V100) object's setup panel.
    Image Modified
  2. If the tamper switch is enabled, select the Tamper switch enabled checkbox (1).
  3. Configure the tamper switch A/D limits (see Section Configuring EEPROM Limits)(2).
  4. In the Tamper switch debounce time, msec field, enter the time period (in milliseconds) to be used for fixing (debouncing) the bouncing tamper switch signal(3).
  5. If the AC failure input is enabled, select the AC failure input enabled checkbox (4).
  6. Configure AC failure input limits (see Section Configuring EEPROM Limits)(5).
  7. In the AC failure input debounce time, msec field, enter the time period (in milliseconds) to be used for fixing (debouncing) the bouncing AC failure input signal(6).
  8. If the battery failure input is enabled, select the Battery failure input enabled checkbox (7).
  9. Configure the battery failure A/D limits (see Section Configuring EEPROM Limits)(8).
  10. In the Battery failure debounce time, msec field, enter the time period (in milliseconds) to be used for fixing (debouncing) the bouncing battery failure input signal(9).
  11. If the reset switch is enabled, select the Reset switch enabled checkbox (10).
  12. Configure the reset switch A/D limits (see Section Configuring EEPROM Limits)(11).
  13. In the Address drop-down list, select the interface module's address (12).

    Note
    titleAttention!
    The device's address is set automatically when the object tree is created. Changing the address may lead to losing the connection to the device.


  14. In the Door behavior drop-down list, select the interface's door behavior type (see Section Configuring a V2000 controller's door behavior).
  15. If you want to configure EEPROM, select the EEPROM programmed checkbox (14).
  16. Click Apply to save the changes (15).

...