The SIP-panel is configured as follows:

  1. Create a Go to the Basic settings tab of the SIP-panel object based on the Display object on the Interfaces tab of the System Settings dialog box.
  2. Set the coordinates of the upper left corner of the interface window in the X and Y fields (1).
  3. Set the width and height of the interface window in the W and H fields (2).
  4. From the Monitor drop-down list (3), select the computer monitor on which the interface window will be displayed.
  5. From the Terminal drop-down list (4), select the SIP-terminal object which SIP-devices use the SIP-panel.

    Info
    titleNote

    Each Server/Remote Client should have its own display with its own SIP-panel (see Assigning the displays to the operator workstations). If the display with this SIP-panel is already selected for any computer, the Terminal drop-down list will be inactive. It is necessary to fix the incorrect configuration of the Server/Remote Client.


  6. From the Monitor drop-down list (5), select the Monitor object corresponding to the Video Surveillance Monitor to which the video cameras associated with the corresponding SIP-devices are added. For details, see Selecting and configuring video cameras.
  7. Click Apply (6).

The The basic settings of the SIP-panel is panel interface object are now configured.