- Create and configure an embedded detector in Intellect for the thermal camera, from which it is necessary to receive the face temperature data (see Embedded detectors).
- Go to the settings panel of the Face Recognition Server object. Go to the Analytics tab.
- In the Threshold field (1), enter the temperature in degrees Celsius; when this value is exceeded, the Temperature rise (TEMPERATURE_ALARM) event will be generated.
- Set the Combined work with thermal camera checkbox (2) if it is necessary that the FIND_PERSON event is generated only when the temperature is received from the thermal camera or after the time, specified in the Thermal camera reply timeout, sec parameter.
- Set the Get photo from thermal camera checkbox (3) if it is necessary to receive photos of captured faces from the thermal camera, not from the video camera.
- In the Thermal camera reply timeout, sec field (4), enter the timeout in seconds for the reply from the thermal camera with the temperature.
- Click the Apply button (52).
Configuring the Face Recognition Server operation with the thermal camera is now completed.
...