Go to documentation repository
Page History
...
- Set the Full hexadecimal mode checkbox (3) if it is necessary to use the entire card number in hexadecimal notation.
- Set the Full decimal mode checkbox (2) if it is necessary to use the entire card number in decimal notation.
- In the Get bit range from card data group, set the settings for the received card data:
- Set the length in bits of the card data (3).
- Set the offset in bits of the card data (4).
- Set the Invert byte order checkbox (5), if it is necessary to invert the bit byte order of the card data.
- Set the Invert bit values checkbox (6) if it is necessary to invert the bits of the card data.
- Set the Add high bit checkbox (7) if it is necessary to add the high-order bit to the received data, and select the type of the high-order bit to be added from the drop-down list.
- Set the Add low bit checkbox (8) if it is necessary to add the low-order bit to the received data, and select the type of the low-order bit to be added from the drop-down list.
- In the Get card code from range group, set the settings for the received card code:
- Set the length in bits of the card code (9).
- Set the offset in bits of the card code (10).
- Set the Invert byte order checkbox on (11) if it is necessary to invert the byte order of the card code.
- Set the Invert bit order checkbox (12) if it is necessary to invert the bit order of the card code.
- In the Get facility code from range group, set the settings for the received facility code of the card:
- Set the length of the facility code in bits (13).
- Set the offset of the facility code in bits (14).
- Set the Invert byte order checkbox (15) if it is necessary to invert the byte order in the facility code.
- Set the Invert bit order checkbox (16) if it is necessary to invert the bit order of the facility code.
- In the Facility code field (17), if necessary, enter the facility code, which will be automatically assigned to all access cards.
- Click Apply (18).
...
Overview
Content Tools