- Establish the connection between each server and a UPS.
- Установить все последние пакеты обновлений Windows.Синхронизировать системное время с мировым и установить корректный часовой поясInstall all the latest Windows service packs.
- Synchronize the system time with world time and specify the correct time zone.
- For each Server, specify a unique Windows hostname.
- Specify a new password for the account of local administrator.
- Synchronize the time of all Servers and IP devices.
- Create another administrator account for backup. Specify a password for it.
...
- Use the new port range 20111-20210 (see Network settings utility, Ports used by the Axxon Next Software Package).
- PostgreSQL:
- If possible, do not install it on the system drive (see Silent install (Quiet Mode)).
- Do not install it on the same disk to which the archive is recorded.
- If possible, install it on SSD.
- VMDA database:
- If possible, install it on SSD for faster archive search.
- Consider the disk space required for the database (see Disk storage subsystem requirements). 30 days / 100 cameras ~ 500 Gb.
...
Antivirus configuration (see Appendix 4. Using Axxon Next with anti-virus software)
...
:
-
Skip all scans/verifications regarding the following processes that are listed below:
- consul.exe;
- nomad.exe;
- apphost.exe;
- postgres.exe.
- Skip all scans/verifications for the following folders:
- C:\ProgramData\AxxonSoft\AxxonNext;
- C:\Program Files\AxxonSoft\AxxonNext;
- C:\Program Files\Common Files\AxxonSoft;
- Postgres and VMDA folders if they are not default,.
- Skip all scans/verifications on the following network ports:
- 20109-20210;
- 4000 (only for Failover install installation type);
- 4646-4648 (only for Failover install installation type);
- 8300-8302 (only for Failover install installation type);
- 8500 (only for Failover install installation type);
- 8600 (only for Failover install installation type).
Initial setup:
- Сhange root password (see Working with users).
- For server only: add auto-logout after 1 hour (see Configuring automatic exiting and locking of the Client).
- Create the archive before adding cameras (see Creating archives).
- Activate the licenses (see Creating an activation request, Activation by applying license file).
...
- Connect the cameras to the servers.
- Ensure that the time of all cameras and servers is synchronized.
- Add the cameras to the system (see Adding and removing IP devices, Bulk creation of IP devices). Preferred protocol: ONVIF generic.
-
Green stream:
Make sure that for each camera different stream IDs are selected as High quality and Low quality streams.
- Low quality stream settings should be lower than the High quality stream.
- Codec type: do not use MJPEG*.
- FPS: sub stream fps >= 6.
- Resolution:
- Aspect ratio should be the same for Low and High quality streams*.
- Low quality stream resolution >= 640x360.
- Low quality stream resolution <= 1280x720.
- Bitrate:
Recommended type*: VBR + limit.
Recommended bitrate: 1 mbps per 1 MP.
- Critical: >2 mbps per 1 MP.
- GOV (also known as GOP, I Frame, etc.): fps x2 (2 sec) is recommended.
- Protocol: TCP* is recommended.
- Buffer: 500* is recommended.
*May differ for different camera models.
...