- Ensure Servers are connected to an uninterruptible power supply (UPS).
- Для предотвращения частых обновлений системы, которые могут привести к неработоспособности, рекомендуется использоваться Windows 10 LTSB или Windows Server (see Operating system requirements).
- Install all the latest Windows service/update packs.
- Synchronize the system time with world time and specify the correct time zone.
- For each Server, specify a unique Windows hostname.
- Specify a new password for the account of local administrator.
- Synchronize the time of all Servers and IP devices.
- Create another administrator account for backup. Specify a password for it.
...
- Use the new port range 20111-20210 (see Network settings utility, Ports used by the Axxon Next Software Package).
- PostgreSQL:
- Do not install it on the same disk to which the archive is recorded.
- If possible, install it on SSD.
- VMDA Metadata database:
- If possible, do not install it on the system drive.
- If possible, install it on SSD for faster archive search.
- Consider the disk space required for the database (see Disk storage subsystem requirements). 30 days / 100 cameras ~ 500 Gb.
Antivirus configuration (see Appendix 4. Using Axxon Next with anti-virus software):
-
Skip all scans/verifications regarding the following processesДобавить в исключения следующие процессы:
- consul.exe;
- nomad.exe;
- apphost.exe;
- postgres.exe.
- Skip all scans/verifications for the following foldersДобавить в исключения следующие порты:
- C:\ProgramData\AxxonSoft\AxxonNext;
- C:\Program Files\AxxonSoft\AxxonNext;
- C:\Program Files\Common Files\AxxonSoft;
- Postgres and VMDA folders if they are not default.
- Skip all scans/verifications on the following network portsДобавить в исключения следующие порты:
- 20109-20210;
- 4000 (only for Failover installation type);
- 4646-4648 (only for Failover installation type);
- 8300-8302 (only for Failover installation type);
- 8500 (only for Failover installation type);
- 8600 (only for Failover installation type).
...
- Activate the licenses (see Creating an activation request, Activation by applying license file).
- Сhange root password (see Working with users).
- For Server only: add Client auto-logout after 1 hour (see Configuring automatic exiting and locking of the Client).
- Create the archive before adding cameras (see Creating archives).
- Each archive should consist of two or more volumes. The size of one volume should not exceed 20 TB.
Camera configuration (see The Video Camera Object):
- Connect the cameras to the Servers.
- Ensure that the time of all cameras and Servers is synchronizedСинхронизируйте время всех Серверов и камер с одним NTP сервером.
- Add the cameras to the system (see Adding and removing IP devices, Bulk creation of IP devices). Preferred protocol: ONVIF generic.
-
Multistreaming:
Make sure that for each camera different stream IDs are selected as High quality and Low quality streams.
- Low quality stream settings should be lower than the High quality stream.
- Codec type: do not use MJPEG*.FPS: Low quality stream fps >= *: рекомендуется использовать H.265 или H.264. Если планируется использовать Web Клиент, то рекомендуется H.264 - использование H.265 приводит к рекомпрессии потока на стороне Сервера
- FPS: для корректной работы детекторов частота кадров Low quality stream должна быть не менее 6.
- Resolution:
- Aspect ratio should be the same for Low and High quality streams*.
- Low quality stream resolution >= 640x360.
- Low quality stream resolution <= 1280x720.
- Для корректной работы детекторов разрешение Low quality stream должно быть не менее 640x360 и не более 1280x720.
- Bitrate:
Recommended type*: VBR + limit.
Recommended bitrate: 1 mbps per 1 MP.
- GOV (also known as GOP, I Frame, etc.): it is recommended to have at least one keyframe per second.
*May differ for different camera models.
...
Настройка записи в архив (see
...
Binding a camera to an archive):
- Each archive should consist of two or more volumes. The size of one volume should not exceed 20 TB.
- Link each camera to at least one archive.
- Configure recording to the archive (permanent or triggered by detection tools) for each camera.
-
Make sure pre-recording is enabled (> 1 sec).
-
Note that after you re-create the archive, it is necessary to re-create all recording rules in the detection tool settings or Programming settings.
...
- The motion detection tool should operate on a low quality stream (see Configuring VMD).
- Add privacy masks:
- For the time indicator.
- For uninformative areas of the frame (for example, for a TV).
- Create automatic rules for recording to the archive (see Automatic Rules).
- Use a GPU for the detection tools operation if there is one.
...