Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. It is now possible to relay alarm events from the Server of Control to Telegram bot. Along with the alarm message, the geocoordinates of the alarm object and a frame in jpeg format can be sent
  2. You can now restrict the user's access rights to view the video stream from certain cameras on the Server of Control and Additional workstations
  3. Added a special operator mode on the Server of Control and Additional workstations. In this mode, the operator cannot accept alarms in the Reaction to alarm window and close the alarm forcibly
  4. Windows with information messages in the Monitoringinterface objects now have common style
  5. Improved the Monitoring as a service mode:
    • now during installation, the IntellectServiceUseruser is no longer created which was used to launch the ITV Monitoring Vrecover service by default. Now this service is launched using the LocalSystem by default;
    • when the active account is changed, the Monitoringmodules are restarted
  6. Updated the Agent of Control since the calculation of CPU load in the task manager has changed starting with Windows 8:
    • for Windows 8 and newer OS, the % Processor Utility counter is used;
    • for older operating systems, the % Processor Time counter is used
  7. Now you can select a physical monitor for all interface objects of Monitoring
  8. The following fields in interface objects now have autocomplete option:
    • search by titles field in Search in archive object;
    • filter field in the Alarms report and vehicle number field in the Vehicle LPs report in Monitoring Reports object
  9. Optimized the StreamViewer module for viewing live video:
    • now when you select the All cameras of Partition of Control menu item, only one ActiveX instance of the CamMonitor.ocx component is created with the required number of cameras:
    • the StreamViewer module can now be run with a low priority
  10. Increased the total number of cameras that one Agent of Control can process to 320
  11. Now you can specify the path to the FTP directory located on the Server of Control and intended for interaction with the Central Server of Control
  12. When you select an object in the Monitoringinterface, a corresponding message is sent to the Intellect core.This allows you to implement various work scenarios using scripts, for example, to display the scheme of the selected object

...