Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Command-line option

                        Description

/? or /help

Open the Help window

/x or /uninstall

Remove Axxon One and save the configuration

/x/removeall

Remove Axxon One and delete the configuration

/r or /repair

Repair Axxon One

/qn or /quiet

Silent install

/norestart

Disable automatic reboot of the system during installation

/debug

Log installation

/noOSCheck 

Skip OS compatibility check

/postgresinstalldir="D:\Postgres"PostgreSQL installation folder
/INSTALLTYPE="ServerClient"

Installation options:

ServerClient − Server and Client (default),

raftserver − Failover Server and Client,

Client

/ADD="[]"

Hers Here is the list of components to install or remove (if you remove/uninstall software). See the possible values in the table below.

/REMOVE="[]"

Hers Here is the list of components NOT to install or remove (if you remove/uninstall software). See the possible values in the table below.

/dpcmd="INSTALL_BOSCH_VIDEOSDK=\"no\""

Bosch VideoSDK driver Installation (see notes).

no − do not install,

yes − install

/CMD="[commands]"

Basic installation options and values. Commands are [option] = \ "[value] \" or [option] = [value] '. See available installation options in the table below.

...

Installation options

Description

QUICKLAUNCH_SHORTCUT='1'

Create shortcut:

1 − Yes (default),

0 − No

DESKTOP_SHORTCUT='1'

Copy shortcut to desktop:

1 − Yes (default),

0 − No

INSTALLDIR='[%ProgramFiles%\AxxonSoft\Axxon One]'

Axxon One installation folder

NGP_IFACE_WHITELIST="0.0.0.0/0"

Network interfaces. The default value is "0.0.0.0/0" (all available network interfaces).

Format of network interfaces: "IP-address1 / number of unit bits in the mask, IP-address2 /number of unit bits in the mask"

NGP_ALT_ADDR="0.0.0.0"

Setting the outside local address for a Server behind the NAT).

Format of network interfaces: "IP Address1 or DNS-name1, IP address2 or DNS Name2"

PORT_RANGE_START="20111"

The initial value of the port range for Server. 20111 − default.

PORT_RANGE_COUNT="100"

Number of ports in use. The minimum number is 20. 100 − default.

Options for Server and Client installation

PATH_TO_DATA = 'X:\Axxon OneData',
where X is the letter of the disk with the most free memory

Directory for storing the log database and metadata database. Default is X:\Axxon OneData.

The PATH_TO_DATA parameter should be after the INSTALLDIR parameter.

FBUSER_TYPE='DEFAULT'

User account for file explorer:

DEFAULT − create a new account; the default name selected will be AxxonFileBrowser,;

SYSTEM − select an account from the Local System,;

SPECIFY − create a new account; choose the user name and password.

FBUSER_NAME='[AxxonFileBrowser]'

Setting a user name and password for an account in file explorer.

When you choose SPECIFY of the FBUSER_TYPE parameter

FBUSER_PSW='[Axxon2.0.0]'
CONFIG_PATH='[CommonAppDataDirectory]'

Path to configurations files and folders

DOMAIN_NAME_TYPE = '[NewDomain]'

Select Axxon-domain:

NewDomain − create new Axxon Domain (default),;

WithoutDomain − do NOT add Server to Axxon Domain,;

TheSameDomain − use existing Axxon-domain.

WHATDBUSE = '[EXIST]'

EXIST − use existing log DB (default)

NEWDB − create new DB

WHATVMDADBUSE = '[EXIST]'

EXIST − use existing object tracking DB (default)

NEWDB − create new DB

The command for silent installation of Axxon One may look like: