Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Set the control device address: Select System - Network Network in the device internal menu, then disable DHCP and set IP address and gateway.
    Image Modified
  2. Set the Axxon One server IP address and port on the device: Open the device web interface by entering the above set IP address in the web browser, then select Platform Access - Third-Party Platform.

    Info
    titleNote.

    The web interface is only available on https by default, so please use https prefix before the IP address.

    Image Modified

  3. Set the 8. Private VMS mode in the device's internal interface.
    Image RemovedImage Added
  4. Transfer the PTZ control device to operating mode by one of the following actions:
    1. Select any monitor MON (monitor) [integer in the range 1-9999], any camera CAM (camera) [integer in the range 0-999999]; in this mode all keys will work, including the WIN (subwindow of video wall) and MULT (layout size) keys for the monitor and camera.
    2. Select any camera CAM (camera) [integer number in the range 1-999999 (number 0 is available only when setting the monitor)]; the WIN, MULT and CAM-G keys will not work in this mode.
    3. Select any monitor MON (monitor) [integer in the range 1-9999] and any group of cameras CAM-G (camera group) [integer in the range 1-999999]; in this mode, only the MULT, OK keys and the rotations of the joystick axes will work.
      Image AddedImage Removed

      Info
      titleNote.

      To select these parameters, enter a number on the device keypad, then press the corresponding key (MON / WIN / CAM / CAM-G).

      If the the server IP address and/or port is not accessible from the PTZ control device, the "Connect failed" message will be displayed on the control device screen after pressing the MON / WIN / CAM / CAM-G keys.


...