Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Manually add the Interop IP device to the configuration (see Adding and removing IP devices);

  2. Enable The Embedded Storage storage object.
  3. Specify the address of the device in the following format (1): <IP-address of local server>:<name of local server in Axxon domain>:<ID of camera on server>.

    Note
    titleAttention!

    The Server name is case-sensitive. 

    If the name is Server1, no connection will occur if you enter server1 or SERVER1.

  4. Specify a port of the local Server from which data is transmitted (2). If you use TCP protocol (see 8), please specify the RTSP port number (554 by default, see Configuring an RTSP Server). If you use rtspoverhttp or rtspoverhttps protocol, specify the web Web server's port (80 by default, Configuring the Web server-Server).

  5. Specify the user name and password (3). The user must have permissions to access the local server.
  6. If you want to display live video from the local server when it is available, select Yes in the appropriate field (4).
  7. Specify the maximum playback speed (5).
  8. Select the data transfer protocol (6).

  9. Click the Apply button.
  10. Repeat the above steps for all the required cameras from all local servers.
  11. Configure automatic replication from the embedded storages of the added devices to the centralized server archive (see Configuring data replication).

    Note
    titleAttention!

    With a high network load, there may be gaps in the centralized server archive.


...