Go to documentation repository
Page History
Information about the status of cameras can be displayed in three ways, chosen via the buttons in the upper-left corner of the board:
- as As diagrams.
- as As diagrams with text.
- as As a table.
Info | ||
---|---|---|
| ||
Disconnected cameras are displayed at the end of the list with dimmed brightness. |
...
The percentage rate of actual video fps to the camera's high definition stream fps setting (see The Video Camera Object).
- Status of detection tools (loss of quality, position change, motion).
- Depth refers to the number of hours or days from the start of the earliest video stored in any archive to the end of the most recent video (if archive recording is not configured for the camera, this section is colored gray on the diagram).
Average recording time, in hours per day, is the ratio of the total recording time to to the age of the archive archive/retention time (time from the earliest stored video to now).
Info title Note For constant recording, this parameter value is equal to 24 hours. If the recording takes 50 percent of total time, the value is 12 hours.
- Remaining time for replication of the archive.
...
If there is no signal from a camera, the appearance of the diagram changes accordingly.
Information about detection tools is received in real time. Depending on the status of detection tools, the corresponding icons change color:
- Green – detection tool status is normal.
- Red – detection tool activated.
- Gray – detection tool disabled.