If you install INTELLECT™ Axxon PSIM™ software on computer where an earlier version is used, then installation will be in the updating mode.

Info
titleNote.

Update the Intellect Axxon PSIM software on Remote Clients while its updating on the Server or on Remote Admin Workstation.

The compatible versions of the Intellect Axxon PSIM software should be installed on Remote Clients and on Server/Remote Admin Workstation, i.e. the first two digits of version number should be the same (e.g. versions 4.10.4 and 4.11.0 are not compatible, but versions 4.10.3 and 4.10.4 are compatible).

Intellect Axxon PSIM since version 4.10.2 is not compatible with earlier versions in the distributed configuration.

...

Note
titleImportant!

It is recommended to create database backup before updating – see Creating the database backup copy.

To update INTELLECT™ Axxon PSIM™ software, do the following:

  1. Unpack the installation kit as described in Getting ready for Axxon PSIM installation; the destination folder will show the contents of the kit.
  2. Run the setup.exe file to start the INTELLECT™ Axxon PSIM™ software installation procedure.
    As a result the dialog box of choosing language is displayed.
  3. Choose the language of INTELLECT™ Axxon PSIM™ software installation and click Install.
     
    As a result the Type of installation dialog box is displayed.
  4. Choose the type of installation needed.
  5. To log all installation events, set the Enable full installation log checkbox.

    Info
    titleNote.
    While installing and uninstalling the software events are logged to IntellectAxxon PSIM.log and Intellect Axxon PSIM uninstall.log correspondingly. To collect log-files, the “Support.exe” tool is to be used (seeThe utility for collecting configuration data on servers and RWS for the Technical Support section).


  6. Click the Next button.
    The Selecting components for installation dialog box is displayed.
  7. Set the checkboxes next to the components that are to be installed.

    Info
    titleNote.
      All offered components are recommended to be installed.


  8. Click the Install button.
    The selected prerequisites and drivers will be installed. 

    Note
    titleAttention!

    If Intellect Axxon PSIM is updated to a version whose second and/or third number is larger than that of the currently installed version (for example, from version 4.10.4 to 4.10.5, or 4.10.4 to 4.11.0), compatibility is lost with industry-specific vertical solutions built for old versions. This is why, during the installation process, you are asked to remove industry-specific vertical solutions.

    To remove industry-specific vertical solutions that are installed on the computer, select Yes. Otherwise, problems can occur when starting Intellect Axxon PSIM after update.


    When prerequisites and drivers are installed, the dialog box of INTELLECT Axxon PSIM update is displayed.

  9. Click the Next button.
    The dialog box of the type of update is displayed.
  10. Select one of the offered types of update.  The types of update are described in the table below

    The types of update

    Description

    Save system settings

    Use of settings chosen for installation of an earlier version

    Configure system settings

     Switch to step-by-step system configuration. Step-by-step configuration is described in Installation of INTELLECT™ Axxon PSIM™ software as a Server/Remote administrator workplace section.


  11. Click the Next button.
    When the system is configured, installation of INTELLECT™ Axxon PSIM™ software starts.

    Info
    titleNote.

    Error of driver installation for the FX4 card can occur while the Intellect Axxon PSIM software update on the Windows 7 SP1 operating system without Internet connection. To eliminate this error install the following missing Windows updates:

    https://support.microsoft.com/en-us/kb/3004394

    https://technet.microsoft.com/en-us/library/security/3033929


  12. As a result the Update Complete dialog box is displayed.
  13. Click the Finish button.

    Info
    titleNote.
    Then the Axxon Driver Pack will be installed.


    The Installation complete dialog box is displayed. It contains the information about INTELLECT Axxon PSIM components mode (installed or not).

  14. Click the Finish button.

...

Info
titleNote.
It is recommended to select the option of closing the program with computer restart.

INTELLECT Axxon PSIM software is now updated.