Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Go to the Hardware tab in the settings panel of INTELLECT Axxon PSIM™ (1).
  2. Create the Relay system object under the Video Capture Device object or select the corresponding object in the object tree in the Hardware tab on the settings panel of INTELLECT Axxon PSIM™ (2).
  3. Specify the ID and name of the Relay object and select the Video Capture Device object to become the parent of the Relay object (3).

    Info
    titleNote

     If the Sensor-Relay card is used, then specify that video capture card with ADC to which the Sensor-Relay card is connected.

  4. Select the Channel number matching the number of output connector to which the relay is connected (4).
  5. In the Executor dropdown list select the type of executive device used as the relay in the guarded area (5).
    The Executor parameter is used for selecting the icon on the interactive map. This parameter is essential for better perception of information (displayed on the map as object icons) by Operator and for real-time intercepting by Operator if required.
    The types of executive devices available for the Relay system object are given in table.

    Executive 

    device

    Description

    Light

    Icon of the interactive map for the device responding 

    to changes in the illumination in the guarded area

    Signal

    Icon of the interactive map for the device 

    responding to sound changes in the guarded area

    Lock

    Icon of the interactive map for the device 

    responding to locking/unlocking a window, door, etc.

  6. Click the Apply button to save the changes.

...